  • Jan 8, 2010, 07:48 AM
    sldcusmcmike
    Can I run my electric furnace on a generator?
    I have a goodman airhandler (mbr1600aa-1aa) with a 15kw heat pack(hkp1500). It will allow me to turn off the 30a breaker and run as a 10k, but I want to be able to turn off the 60a and run it as a 5k for heating my house when powered by a 6250 kn generator. I know I would need to transfer my power supply for my controls off the 60a breaker to the 30a breaker, but what do I do the sync switches?
  • Jan 8, 2010, 01:37 PM
    hvac1000
    Best to post this over in electric. I have done this before BUT I do not conside this a good choice. Check with them.
  • Jan 8, 2010, 01:48 PM
    tkrussell
    What does this mean?

    Quote:

    Originally Posted by sldcusmcmike View Post
    but what do I do the the sync switches?

  • Jan 8, 2010, 02:40 PM
    KISS

    He probably means sequencers, but let him clarify. How Do Sequencers Work in Electric Furnaces? | eHow.com

    I'll comment more later, but I will add:

    It does depend on element size and the elements are usually sized differently. e.g. You could have a 15 KW element and a 5 KW element. The 15's could be made up of two 5's.

    It could take some effort and expense to "make" at 20 KW element behave as any element between 0 and 15 KW. The part to do this isn't cheap.

    An example:

    http://instrumentation-central.com/S...pci_series.pdf

    The manufacturer would have to be questioned to what happens on start-up, power loss/power up, loss of setput signal/restoration

    Something to think about.

    Putting elements in series MIGHT be a possibility,but it might not be the power level you desire. I doubt it would work.

    Eurotherm makes some of the best stuff out there.

    So, it's entirely possible to run a system with such a controller and with a little magic so it so it runs at 100% and X% based using a very small switch.

    You could run it at say 5 KW and 1 KW based on a simple switch. Giving you a total of 15 KW in one one and 6 KW in the other.

    I'd have to brush up before committing to a design.

    One way is to ignore the sequencer's all together, use a small PLC and duct temperature and roll your own.

    6 KW and maybe 5, 10 and 15 KW based on temperature rise.

    Not cheap.
  • Jan 14, 2010, 01:28 PM
    sldcusmcmike
    To be clear, I have 15k total. There are three 5k elements. Tow f them work off a 2p60a and the other off a 2p30a breaker. Ok, I got it up and running. I switched the control power wires from the 10kw(60a) breaker over to the 5kw(30a)breaker. This gave me the 5k heat but no blower. So I switched the blower feed that was on one of the 10k legs, over to one of the 5k legs and all works well. So now, I can have some heat running off my generator when the power goes down. Thanks for your hel folks!
  • Jan 14, 2010, 09:37 PM
    Missouri Bound
    I'll assume you have an all electric home. Are you planning to run anything else on the generator?
  • Jan 15, 2010, 05:04 AM
    sldcusmcmike
    No, it's got propane for dryer and stove. Every year, the power goes out after ice storms for a couple days. We can get by with just the furnace and a light or two. This was for emergancy heat only.
  • Jan 15, 2010, 09:09 AM
    Missouri Bound
    We have a similar situation here in Missouri with ice storms. I purchased a small propane stove / fireplace for part of the house to take care of the heat and left the furnace alone. And I do have a generator to take care of the freezer and refrigerator, and necessary lights.