    delboyisaacs Posts: 2, Reputation: 1
    New Member
     
    #1

    Jun 12, 2013, 10:20 AM
    Power Craft Generator
    I purchased a Powercraft 800 watt generator in Dec. 2012. I used it once and it performed perfectly. Yesterday I reqired the use of it but it refused to start.
    I get no spark from the high-tension lead. I have checked the on/off switch and all wiring connections. I contacted the service agent as suggested by Aldi, the supplier, they told me they no longer are the service agent for this make.

    Do you know of a common fault affecting this model, e.g.. ignition coil or c.d.I. unit ?
    crigby's Avatar
    crigby Posts: 4,343, Reputation: 107
    Outdoor Power Equipment Expert
     
    #2

    Jun 13, 2013, 07:08 PM
    Hi,
    I gather you are in the UK or Ireland since that is where that brand is sold. Ignitions do not generally go bad sitting. I would disconnect the switch from the engine to test. Fuel problems are the most common problems especially from sitting. I did find a manual for a two stroke generator at:
    http://doc.servotool.eu/documents/PG...RE-1101-17.pdf
    Peace,
    Clarke
    delboyisaacs's Avatar
    delboyisaacs Posts: 2, Reputation: 1
    New Member
     
    #3

    Jun 14, 2013, 04:00 AM
    Quote Originally Posted by crigby View Post
    Hi,
    I gather you are in the UK or Ireland since that is where that brand is sold. Ignitions do not generally go bad sitting. I would disconnect the switch from the engine to test. Fuel problems are the most common problems especially from sitting. I did find a manual for a two stroke generator at:
    http://doc.servotool.eu/documents/PG...RE-1101-17.pdf
    Peace,
    Clarke
    Hi, thanks for response but I have tried with switch dissed, still no high tension.
    Best regards, delboyisaacs.
    crigby's Avatar
    crigby Posts: 4,343, Reputation: 107
    Outdoor Power Equipment Expert
     
    #4

    Jun 14, 2013, 07:51 AM
    Hi,
    If you have access to an ohmmeter, you may wish to check the impedance of the ignition module. Both the primary and the secondary windings will share ground at the laminate legs of the armature. The ignition ground wire leads to the primary and it should have a low resistance usually on the order of under 100 ohms, but it could be as high as 2K ohms depending on the electronics internally. The secondary will be the spark plug lead and will typically be on the order of 30K - 35K ohms. A zero reading would be a short and no reading would be an open. In the case of the latter on the secondary, be suspiscious of the of the plug cap/connector. These are not hard and fast readings; some secondaries go as high as 60K ohms and some spark plug caps have a built in 5K ohm resistance. Of course, in each case the circuit is checked to one of the armature legs for the complete circuit.
    Peace,
    Clarke

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Electric Power vs Generator Power [ 3 Answers ]

My home electrical power went out during the Storm Sandy. I switched over to my generator for power. I used the generator to run my furnace. My furnace is a two year old Lennox 2 Stage Gas Furnace. I was told by rhe company I purchesed the furnace off , NOT to run the furnace of the generator.I...

Will it hurt a gas furnace if I use a generator for backup power during a power outag [ 1 Answers ]

Will it hurt a gas furnace if I use a 3500 watt generator for backup power during a power outage?

I require for a Power Plus 5000 Generator 1 generator under following specifications: [ 1 Answers ]

I require for a Power Plus 5000 Generator 1 generator under following specifications: 5000 Watts, 120V, 1 Phase, 60 Hz at 3600 RPM, 3720 RPM at no-load. Thank you, Publio


View more questions Search