    Upstairs bath addition vent lines
    I am adding an upstairs bath with a shower/toilet and vanity. The 3" drain pipe comes up from below near the corner of the room. From there i will run a 3" drain line horizontally to pick up a shower drain approximately 18" from the vertical drain pipe and a toilet approxiamately 48" from the vertical drain. The vanity on the opposite side of the room will have a 2" drain that will tie in near the vertical drain and will be vented with an air admission valve.

    For the shower and toilet will one vent 2" line located between the shower drain and the vertical drain pipe be sufficient for proper drainage?
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Oct 10, 2009, 05:07 AM
    Hi Desartain:

    Are there any fixtures connected onto that 3" drain pipe that "comes up from below near the corner of the room"?

    If the bathroom below connects into this stack then you cannot connect into this stack upstairs as it will be a VENT STACK for the bathroom below and you can't connect into the vent stack with waste from above.

    If this is the case, then you will need to go below the waste pipes from the bathroom and cut into the waste piping down therer and send up a new 3" PVC waste stack. You would pipe the bathroom up and either connect the 2" vent from the bathroom into the existing vent stack (YUP! OK to do with vent on vent) or penentrate the roof separately with a 2" vent.

    Let me know more about the pipe in the corner. Oh!! And yes, one 2" vent for the toilet and the shower will be fine as long as they allow WET VENTING in your area...BUT it needs to be done quite specifically... ;)

    MARK

    .
    desartain's Avatar
    desartain Posts: 2, Reputation: 1
    New Member
     
    #3

    Oct 11, 2009, 01:18 PM
    Mass plumber - Thanks for your reply.

    The 3" line from below runs into the ground and then Y's into the main drain line going to the street. There are no fixtures on it and the other bath and fixtures from downstairs vent to the attic on separate lines. I plan to vent this new line with a new vent line through the roof. We are in a rural area with no codes in force.

    How do I need to run the vent for both the toilet and shower?

    Quote Originally Posted by massplumber2008 View Post
    Hi Desartain:

    Are there any fixtures connected onto that 3" drain pipe that "comes up from below near the corner of the room"?

    If the bathroom below connects into this stack then you cannot connect into this stack upstairs as it will be a VENT STACK for the bathroom below and you can't connect into the vent stack with waste from above.

    If this is the case, then you will need to go below the waste pipes from the bathroom and cut into the waste piping down therer and send up a new 3" PVC waste stack. You would pipe the bathroom up and either connect the 2" vent from the bathroom into the existing vent stack (YUP!! OK to do with vent on vent) or penentrate the roof separately with a 2" vent.

    Let me know more about the pipe in the corner. Oh!! And yes, one 2" vent for the toilet and the shower will be fine as long as they allow WET VENTING in your area...BUT it needs to be done quite specifically...;)

    MARK

    .
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Oct 14, 2009, 04:27 PM
    Hi Desartain:

    Sorry, it's the beginning of heat season around my parts so I've been busy with heat calls the last few days... ;)

    I'll pop in tomorrow and draw up some basics on venting.

    Thanks...

    MARK

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Plumbing Vent Addition [ 1 Answers ]

We are building an new shower and we alreadly have a existing vent for the washer,utility sink,toilet, and dryer. Do we need a separate vent for the shower.

Concerned about possible water damage, upstairs addition and basement footings [ 3 Answers ]

My wife and I bough our house 6 months ago and I am becoming concerned. It is one of the old, in town trendy homes that come with a lot of character an obviously a lot of problems too… Basic info on the home (all work listed is within the last 3 yrs): ·1938 YOC *Brick home (upsatairs addition...

New Addition and A/C vent placing [ 7 Answers ]

Hello I am placing an add-on to my home. 513sqft, 35' x 15' I have one side of 35' wall with 5 large windows and the room is a valted ceiling. Iam placing an a/c to the addition from my exsisting air handler with a 10in duct and reduced to two 8in duct and vents that will be placing in the...

BAsement Bath addition [ 1 Answers ]

I plan to add a bath in my basement. However, there is not a rough in. The house's plumbing is connected to a septic system. The pipe going out to the septic is located about halfway up the basement wall. The plumbing from the upstairs is exposed, as the basement is not finished. However, I...

1ST Floor Bath addition [ 5 Answers ]

I am hoping someone can offer advice. I currently live in the NE in a 1/2 double home that is 80+ yrs old. Approx. 25 yrs ago an additional room was added to rear of first floor (nothing is above this room). This room currently has a large sink. I would like to/in process of gutting the room to...


View more questions Search