    I am building a house & would like to know the code requirements for venting my drain
    I am building a house & would like to know when & where I need to put vents for my dwv?
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    Oct 18, 2008, 08:31 PM

    What State are you in ? What City ?
    remodeling4u's Avatar
    remodeling4u Posts: 4, Reputation: 1
    New Member
     
    #3

    Oct 18, 2008, 08:46 PM
    I live in hutchinson ks
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #4

    Oct 18, 2008, 08:51 PM

    Wait for MassPlumber2008 or Speedball. They come in in the morning. They'll guide you through it...

    I work under strict UPC in So.California that makes things too complicated and way too expensive for you guys in other States.

    But I'll follow your project from distance...
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #5

    Oct 19, 2008, 06:59 AM
    Quote Originally Posted by remodeling4u View Post
    I live in hutchinson ks
    My live in roomie comes from Hutch. She's up there now and will be back in Florida next week. Small world!
    I am building a house & would like to know when & where I need to put vents for my dwv?
    First of all, in every state, every fixture that has a trap must be vented.
    Having said that let me show you how a typical bathroom group will go down.
    Toilet connects to sewer main or the stack vent. Lavatory connects to toilet drain and runs a vent off the top the stubout tee out the roof or revents back into a dry vent in the attic.. The toilet wet vents through the lavatory vent and the tub/shower connects to the lavatory drain and is wet vented by it. This is a normal rough in and is acceptable both by local and state codes and also The Standard Plumbing Code Book in 90 percent of the country.( Milo's in the excluded 10%) The vent off the lavatory may be run out the roof or revented back into a dry vent in the attic or if you're reventing back into a fixtures dry vent you must make your connection at least 6 inches over that fixtures flood rim.
    If you're going t do the work yourself we can hold your hand and walk you through the installation if you wish.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Building code requirements [ 2 Answers ]

What are the building code requirements for electrical service (e.g. 100 amp, 200 amp) and when did they come into effect for Ontario and/or Alberta Canada?

Building code door clearance [ 9 Answers ]

I'm remodeling a bathroom, and the sink/vanity will go against the wall adjacent the door, so I'm wondering how close I can legally put it to the door. The image below is my rough layout. Is there code related to how much clearance a door must have? The door opens to the outside, so obviously I'm...

Venting Requirements for Bathroom in Basement [ 5 Answers ]

It is my desire to install a sink, toilet and small shower in my basement. Nothing is currently “stubbed” in. My question concerns the Drain/Waste/Vent system requirements associated with this project. In the area of the basement where I want to put this bathroom, I have a 4” vertical...

Florida Landlord Building Code Responsibilities [ 1 Answers ]

My daughter recently signed a lease for her first apartment. The lease states that the apartment will be accepted "as is". However, I feel there is a building code problem. The apartment is on the second floor, and there is a small deck/balcony - wood constructed. The deck suffers from major...


View more questions Search