Search:
Type: Posts; User: adkhkr
Search:
Search took 0.00 seconds.
-
Slow but steady lol
Working my way towards tackling the fernco fitting that needs to go.https://uploads.tapatalk-cdn.com/20191207/7b67e52d6ad2e133f59fc3fd885e7c0d.jpg
Sent from my SM-N975U1...
-
For the toilet plumbing, does this look right?
4x3 closet bend to 3x3x2, with the 2in vent going up the wallhttps://uploads.tapatalk-cdn.com/20191206/dc19111dd5e1f3f14415c4ea8feab60e.jpg
Sent...
-
Except for the rest of the pex supply lines, this wall is done. This was a tough one. https://uploads.tapatalk-cdn.com/20191201/972a85138f4edaf3b5315b72199c3fbd.jpg
Sent from my SM-N975U1 using...
-
Got sidetracked this week but here is the sinks completed less the venting...I'll message you, thanks!https://uploads.tapatalk-cdn.com/20191124/0c94d1628e360588f67bc55edc3e5fd5.jpg
Sent from my...
-
Managed to find the fittings online...had some issues getting the straight section in hence the 2 couplings. https://uploads.tapatalk-cdn.com/20191113/088808cc3d94def659e3edf57d842713.jpg
Sent...
-
This should work, just have to turn it 90 into the wall from the wye. Have to hack the stud to get it in there but it should work. How does it...
-
I can squeeze in the double wye 2inch and put in a 2 to 1.5 bushing for the stub outs. Here is the layout, does this look good? The blue is the 3 inch, the red from the side is the 2 inch vent. I...
-
Got the vent for the sink and shower in coming around the corner. Does this look good? Where the 1.5/1.5 inch pipe transition to the 2 inch, is the fitting I used correct? And I used a vent elbow,...
-
See attached...doing the drains back to back isn't going to work. With that said, what option do I have given the separation between each sink? Would a 2" circuit vent like the one in the pic be...
-
I had my sink layout wrong.. the attached picture is the correct layout.
1. Can the red drain line be 1.5"?
2. How to the vents go with this...
-
Finally getting back on the project.
In this photo...I have the following questions.
In red...are those Wye fittings?
In green...is 1.5" sufficient for the drain lines?
In Blue...is 1.5"...
-
Here is a revised layout... Any more suggestions? https://uploads.tapatalk-cdn.com/20190819/0ecbe46c11734951844e64820d5a2d2e.jpg
Sent from my SM-N960U1 using Tapatalk
-
This is what I had in mind where the 4 inch pipe splits.... And than cap the top of the pipehttps://uploads.tapatalk-cdn.com/20190711/66fa5d1d516b496199a96b6c4d255664.jpg
Sent from my SM-N960U1...
-
Thanks for the input... Here is a revised sketch based on your comments.
Any better? https://uploads.tapatalk-cdn.com/20190709/9c62f7fdf2d662e0674091791331f25d.jpg
Sent from my SM-N960U1 using...
-
Hi -
I am doing a Master Bath renovation and changing the plumbing locations. Also, in the future I will be redoing my kitchen and eliminating a wall where the main waste line runs so basically,...
|