    Hot Tub wiring
    I installed a gfi breaker at the main box but wanted to double check my work. The neutral white wire from breaker goes to the ground bar. But does the solid copper ground lead go their also?
    Thanks
    omzig's Avatar
    omzig Posts: 119, Reputation: 19
    Junior Member
     
    #2

    Nov 9, 2006, 07:57 PM
    If this is your main service panel, then yes, the bare equipment ground connects to the same ground bar as the neutrals. If there are two ground bars in the main service panel, they should be connected together and neutrals and equipment grounds can go on either bar. If your new breaker is in a subpanel, then there should be a neutral bar and an equipment ground bar that are separate and not connected together.

    Use caution when working in your service panel. Even if you shut off the main, the main lugs are still hot. Be especially careful when snaking the bare ground wire around, if it touches one of the main lugs you could be in a heap of trouble.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #3

    Nov 10, 2006, 03:40 AM
    Just to be sure this is clear, the Main Panel must have the Main Breaker in that panel, along with all the other branch circuit breakers

    The reason I reiterate this is that many times there is only one panel for a dwelling, so it is perceived as a Main Panel, however, the Main Breaker can be elsewhere, such as at the outdoor utility meter.

    Many newer homes have the Main Breaker outdoors at the meter. This practice has been widely popular for the last 10-15 years.

    When the Main Breaker is not in the "Main Panel" , this panel is now considered as a subpanel, and the neutrals and grounds must not be connected together.

    I cannot express how important this is, the neutral and grounding must be done correctly and is done differently in different panels.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Wiring Hot Tub and using a 50 Amp Double Pole GFCI Circiut Breaker [ 10 Answers ]

:confused: I keep getting the GFCI breaker tripping after wiring my hot tub. I wired 2 hot Red and Black to the proper terminals and the White to the neutral and the Bare Copper to the ground Post at the tub. I am using 6-3 w/G per instructions. Could the GFCI breaker be bad? When I wire...

No Hot Water to shower head, but Hot water to the Tub? [ 2 Answers ]

My husband and I just purchased a new house. We have found that the shower pressure in the bathroom is wonderful however once you have set the right temp from the tub spout and switch over to the shower no hot water makes it to the shower head. We can only turn off the cold water completely in...

Hot Tub Electrical Wiring [ 1 Answers ]

I am getting ready to install a Dimension One spa that the manufacture calls for using #6-3 awg wire and 240 Volt - 50 Amp with a GFCI breaker and disconnect. I had the house pre wired for a hot tub and 240 Volt service. They installed a 50 Amp breaker in the main box and ran about 40...

Hot tub g.f.I [ 1 Answers ]

I recently hooked up a hot tub that required a 240v with no neutral. (50A) I took a two pole 60 from the main service and ran 6/3 teck cable to a 2cct outdoor enclosure outside to within 5' of the tub. Into the enclosure I hooked up the red to the main the black to the other main and the blue to...

Hot tub 240 [ 1 Answers ]

I have a 240 hot tub but no 110 close. I was thinking about running a line to the hot tub controls and use 1 leg of 240 circuit to make a 110 outlet. Bad idea?


View more questions Search