    Well pump pressure issues
    Have a Wellsaver 20 lb tank. The other day we noticed the water pressure increased quite a bit. Called a plumber we know and he said the tank pressure was too high (45lb setting) and adjusted it for a 30-50 psi system. Can't explain why the pressure settings changed. This worked fine until the next day when the water pressure was low and the pump started cycling off/on every few seconds when water was being used. Checked the tank pressure again and it was back up around 45lbs. When I drained the tank to check the pressure reading I only got about a cup of water to drain. Set the tank pressure at 28lbs and turned the system back on. Worked fine for about 7 hours then the pump started cycling on/off again. Again the tank pressure was in the high 30s. Reset the pressure again for 28lbs ands is working fine again. Seems I have to reset the tank pressure after several our of water usage. It is attached to a Culligan N8 water softener.

    Any suggestions on what's going on? Tank appears to be OK, no water coming out of the air valve, tapping side indicates it's not water logged. Pump appears to be running fine. Waiting for the plumber to get back to me.
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    Jan 18, 2017, 11:37 AM
    The tank pressure will vary while the system is on. As the pump fills the tank with water, tank pressure goes up. When the pump cuts off, pressure will drop as water is used. Setting the tank pressure should always be done with the system off and the pressure drained to zero by turning on a low level faucet until the system pressure drops to zero. Then you set the tank pressure by using the air valve at the top of the tank. In your case, it should be at 28#.

    As to why the pump is short cycling, that is generally the result of a waterlogged tank, but if that is the case it will do it every time when water is being used, not just occasionally. That being the case, it is hard to say what is causing your problem. I think your plumber will start with the pressure switch and then look at the pump. I'd like to see if the pressure switch itself is causing the short cycling, or if that seems to be a pump issue.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Jet pump pressure switch issues [ 7 Answers ]

My jet pump was working fine until we replaced the filter... now the pump will not turn on until there is no water left in the bladder and no water is being delivered to the house. After approximately 45 seconds the switch will activate and the pump will run returning the bladder back to its normal...

Are there any issues with using a pump for water pressure in your house [ 2 Answers ]

I am having my bathrooms refitted, and am having 2 power showers and a whirlpool bath installed. The plumber has fitted a pump in our loft to use with the 2 power showers. My question is this - the water pressure to our bath is terrible - it takes over 30 minutes to fill half way up. The plumber...

My private well started with sediment, then pressure issues now no pump. What to do? [ 8 Answers ]

My private well started showing extra sediment, then the pressure started to reduce during showers, now the pump don't seem to be working. Where do I start?

What is the correct suction pressure and head pressure for a 3 ton tempstar heat pump [ 1 Answers ]

When the yellow jacket brand gauges are put on a 3 ton Tempstar heat pump what should the correct suction pressure and head pressure be. I suspect it to be overcharged in freon. Because it is freezing the compressor, accumulator tank and all the lines soild ice.

Pressure tank and well pump switch issues, water stoppage is getting annoying [ 9 Answers ]

The well is reportedly 350 feet deep, Franklin pump control rated for 1hp Square D pressure switch Champion bladder tank about the size of a 30 gallon water heater One inch cast iron Inlet from the pump. I suffered from low water pressure for a couple of years, then started messing with this...


View more questions Search