    jagruti patel's Avatar
    jagruti patel Posts: 1, Reputation: 1
    New Member
     
    #1

    Apr 21, 2007, 09:30 AM
    Our house is built in the year 2000. We have a well system and lately our pressure drops when we use it. For a second, water trickles down and then stops until the pressure is back again. This is happening for a few months. Do you know what is wrong with it? We have a Well-X-troll tank by Amtrol and the normal pressure is about 55 psi. The model number is WX - 252
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Apr 21, 2007, 12:07 PM
    I moved your post. It didn't belong tacked on to another question. You're going to hafta check your bladder tank and after that, if the tank's OK, the check valve.
    Let me explain the function of a bladder tank. Pressure and bladder tanks provide a air cushion that produces water pressure in your system so your pump doesn't kick on every time you draw a glass of water. A bladder tank has a neoprene membrane in the center. As the pump puts water into the bottom half of the bladder tank the membrane compresses the air in the top half. When the pressure reaches the cut off point in the control box the pump shuts down. However you still have between 40 to 50 pounds of pressure pushing the water out to your system. As the pressure drops in the tank when you make a draw the pump kicks on and everything starts over again.
    To check, take something metal and start rapping at the bottom of the tank and work upwards. You will hear a "clunk" in the bottom half full of water. On the upper half you should hear a "clink" because the upper half should have nothing but air in it. IF the sound doesn't change or changes close to to tank top then the bladder tank must be replaced. Your air setting on the tank should be 2 pounds UNDER the cut in point in the pressure control box. If your pressure control has a 20 PSI cut in and 40 PSI cut out the tank pressure should read 18 PSI. This should be done with the pump off and no pressure in the system. Hope this helps and thank you for rating my reply. Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Surging water pressure & leaking water heater relief valve [ 19 Answers ]

Just recently the pressure of our water in the house surges when we turn a faucet on, and the city water company verified that our pressure in the house when we open a faucet is higher than the pressure in the lines in the street, and after the water runs is at a normal pressure (meaning their...

House water pressure from well losing pressure [ 2 Answers ]

I have a well at my home that provides the primary water . I have replaced the well pump with a new one, the pressure tank was bad replaced it, pressure switch was bad replaced it. Now I cannot maintain pressure through out my house. The initial pressure is good for about 10 seconds then it slowly...

Low water pressure in an area known for high pressure [ 3 Answers ]

Greetings, My wife and I are in the process of updating 1957 side by side split level. The previous owner (OK, my Mom as I bought the house I grew up in from her) said that when they moved in they had to install a pressure reducer into the line. I have searched high and low but, I can't see...

Well Water at 20 psi - then drops! [ 3 Answers ]

Do I need a new well? I have had low water pressure for about a week. I checked the pressure tank and pumped it up to 60 psi. Is that too high - too low? Did not fix the problem. We have a well. Water table is fine - east coast. I checked the pressure gauge of the pump and it is 20 -...


View more questions Search