    Wash machine waste septic tank
    The mo. Septic tank inspector said that I need to run my gray water [washer ]into the septic tank doesn't this hurt the septic system?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Feb 9, 2010, 07:17 AM
    Quote Originally Posted by ;
    The mo. septic tank inspector said that i need to run my gray water [washer ]into the septic tank
    Your inspector gave you advice that could clog your system. Kitchen, especially if you have a garbage disposal) and washer discharge should be routed through a grease trap, (see image) before going into the septic tank and out to the drain field.
    The reason for this is to trap and contain the lint and fiber from the washer combined with the grease and garbage from the kitchen before they get out in the drainfield and clog up the holes in the drainfield tiles so they can no longer dissipate the liquid from the septic tank.
    When that happens you're faced with the expense of repairing the drainfield. In my area septic systems are never inhstalled with out a grease trap. It only makes good sense. Good luck, tom
    Attached Images
     
    MaineSiteEval's Avatar
    MaineSiteEval Posts: 6, Reputation: 2
    New Member
     
    #3

    Feb 10, 2010, 08:47 AM

    In my opinion, modern septic systems are designed to handle laundry waste. Use biodegradeable detergent and limit chlorine use and space out laundry loads. If your laundry is discharging to a ditch, that is a violation.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Septic Leach Bed Leaks Back into Septic Tank [ 15 Answers ]

Every time we get a heavy rain I get water coming from the leach bed back into the septic tank. Is there a check valve that can be installed to prevent this from happening or any other suggestions? I have been told that a curtain drain would help, but that is costly.

Sump pump and washing machine ran to old septic tank [ 7 Answers ]

Is it acceptable to have a sump pump and/or a washing machine discharge into the old septic system on a 36 year old house,( the house is know on sewers). I realize this would have been acceptable at one time, but the septic tank and drywell are no longer in use.

Dog Kennel Waste Management Septic Tank System [ 1 Answers ]

Good morning Blake, The line would have to be trapped and vented at the runoff trough. You would use PVC pipe and fittings to do this and make the trap and drain 3". Since this will be a run off for dog poop what will be the wash down set up? A simple hose bib or a timed flush arrangement ? ...

Septic Tank Odor Outside When Washing Machine Drains [ 1 Answers ]

When my washer drains, the water flows into my septic tank. Immediately, septic odor comes from the septic tank area outside (not from the washer, not inside the house). I suspect that the volume of water is displacing some stinky gas and it is not escaping where it should. Where should that gas...

Bath wash basin has extra waste pipe [ 1 Answers ]

The waste pipe on my bathroom basin has an extra pipe about 1/2" dia joining it just below the drain hole in the basin and before the trap. The pipe is flexible and goes off into the wall. Is it an extra drain for something? There is an air conditioning unit in the roof above. The main waste pipe...


View more questions Search