Ask Experts Questions for FREE Help !
Ask
    MarkinMI's Avatar
    MarkinMI Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 13, 2010, 02:26 PM
    Vent Stack
    I am having a problem with a bathroom sink totally backed up. I can solve most problems with snakes or CO2 cartridges, but this one has me baffled. All of the other drains attached to the vent stack are working properly (tub & toilet). I took everything apart and snaked out the drain behind the wall. I then used a Drain King attached to a garden hose. The water just went up the stack vent and spilled out on the roof, and I still have a clogged drain. Later, I went up on the roof and can see water about 10 feet down (the total length of the vent stack is about 20 feet. Everything below the bathroom sink drain is working properly (tub drain, toilet, and basement shower drain, basement toilet, and basement sink. I was thinking about snaking out the vent stack, but I'm worried I may push any object further down and clog the rest of my drains (tub & toilet). The sink drain is 2 inch galvanized, and the vent stack is 4 inch cast iron. One story ranch house with basement was built in the late 50's in Michigan. Is this something that I can do myself?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Oct 13, 2010, 03:55 PM
    Quote Originally Posted by ;
    The water just went up the stack vent and spilled out on the roof,
    You have a blockage at the base of the stack that must be snaked from the roof. You might want to rent a regular sewer machine,(see image) to do this. Put out enough snake to reach the base and 18 feet more. Leave your Drain King in the house when you go up on the roof. Good luck, Tom
    Attached Images
     

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Old stack vent system vent tub [ 8 Answers ]

I wrote in another thread about my slow draining tub. The consensus is that I need a vent, preferably downstream from the sink ( many mentioned an AAV just beyond the trap) now my issue is that I have a pedestal sink, and the plumbing is not really accessible around the sink to put in any kind...

Stack vent [ 7 Answers ]

I am installing a second kitchen in my basement and have a couple of questions about the vent. I can go up into the attic by making one 6' horizontal run and then straight up through two stories. I am then about 5 or 6 feet away from a horizontal run(sloping the opproprate 1/4 " per ft) that is...

No vent stack - possible? [ 4 Answers ]

We've been living in a house for 3 years and have been doing some remodeling throughout. It appears that there is no venting system in the house. There are 3 toilets, 4 sinks, and 2 showers, however we cannot find a vent stack anywhere. My roofer noticed this when he took off the old roof - he...

Is It Vent stack? [ 3 Answers ]

Hi, Around late December my kitchen sink started to drain real slow, so I got a snake and snaked out he lines. Pulled back the usual "black goo" and everything seemed to be fine. Then this weekend I doing A little yard work and notice water coming out from behind the siding. Upon further...

No vent stack? [ 3 Answers ]

I recently purchased an old house and the toilet drains slow and bubbles. I cannot locate any plumbing venting at all. The plumbing is all located within 4 ft of the main drain going out through the basement wall, with the kitchen sink, bath sink, tub all connecting to the toilet line then out...


View more questions Search