                      Sep 30, 2008, 05:02 PM
                  
                 |  |  
  
    | 
        
        
        
       
        
        Vent line
       
                  
        Hi plumbing experts,
 I'm running a 1-1/2" PVC vent line vertically inside an interior (non-load-bearing) 2x4 wall, into an attic space and then up and out the roof.  Problem is that the top plate of this wall lies directly under a joist.  Any advice on how to best deal with this scenario?
 
 Thanks!
 |  
    |  |  
	
		
	
	
  | 
    
      
              |  | Plumbing Expert |  | 
 
                  
                      Sep 30, 2008, 05:27 PM
                  
                 |  |  
  
    | 
        
        
        
       
                  
        Cut the pipe 2' below the plate. Offset it with 2 - 45 degree bends. Continue to the roof.
 |  
    |  |  
	
		
	
	
  | 
    
      
              |  | Junior Member |  | 
 
                  
                      Sep 30, 2008, 05:40 PM
                  
                 |  |  
  
    | 
        
        
        
       
                  
        
	
		
			
			
				
					  Originally Posted by Milo Dolezal   Cut the pipe 2' below the plate. Offset it with 2 - 45 degree bends. Continue to the roof. Thanks Milo... that will cause the 45 section to protrude outside of the finished wall and/or the ceiling - was hoping to avoid that (by notching something?)
     |  
    |  |  
	
		
	
	
  | 
    
      
              |  | Plumbing Expert |  | 
 
                  
                      Sep 30, 2008, 05:43 PM
                  
                 |  |  
  
    | 
        
        
        
       
                  
        Well, let me see if we communicate:
 
 When you are going straight up with your 1 1 /2" vent pipe and you run directly into a joist. Than:  joist is 1 1/2" in width.  To bypass this 1 1/2" joist that prevents  you from continuing straight up , use 2-45's, drill hole through the plate and continue to the roof.... In other words, you will keep the pipe and the 2-45's within the 3 1/2" wall at all times. No protrusions to the ceiling or out of the wall...
 
 Is that correct ?
 |  
    |  |  
	
		
	
	
  | 
    
      
              |  | Junior Member |  | 
 
                  
                      Sep 30, 2008, 06:34 PM
                  
                 |  |  
  
    | 
        
        
        
       
                  
        Thanks Milo.  OK, maybe we didn't communicate :) 
Maybe if I draw this... I was thinking you meant something like this, which I had considered:
   
Maybe if I notch the top plate I can move the 45 section up?  That's where I was headed when I decided to ask here :)
     |  
    |  |  
	
		
	
	
  | 
    
      
              |  | Plumbing Expert |  | 
 
                  
                      Sep 30, 2008, 06:44 PM
                  
                 |  |  
  
    | 
        
        
        
       
                  
        Thank you...  and kudos for the excellent visual !  Now I understand: the joist is running parallel with the wall and sits directly on top of the wall. (... bad framers, bad framers.. :-D  )
 
 You said it: you can notch the joist so you can get into the ceiling. If you have to go straight up in that same area - and you have 2nd floor sitting on top of that joist - than you will have to notch the same joist on top to get back into the upper wall.
 
 You are using 1 1/2" pipes so notches will be small. Also , that joist has plenty of support being positioned directly, and lengthwise, on top of the double plate. I would not worry about structural issues at all...
 
 Once you get into the ceiling, you could also use 90 ell , run your vent to the other nearest wall that doesn't have a joist on top of it - and up to the attic.
 
 Of course, if there is an attic right on top of this joist, than go straigth up w/o notching top or the joist.
 
 Hope that will help...
 |  
    |  |  
	
		
	
	
  | 
    
      
              |  | Junior Member |  | 
 
                  
                      Sep 30, 2008, 06:52 PM
                  
                 |  |  
  
    | 
        
        
        
       
                  
        
	
		
			
			
				
					  Originally Posted by Milo Dolezal   Now I understand: the joist is running parallel with the wall and sits directly on top of the wall. ( .... bad framers, bad framers...! :-D  ) Exactly!  I confess, I am the bad framer :) but the wall had to be exactly there for reasons I won't bore you with!
 
 
	
		
			
			
				
					  Originally Posted by Milo Dolezal   Of course, if there is an attic right on top of this joist, than go straigth up w/o notching top or the joist.  Yes, attic above, can go straight from there.  Thanks so much for your help!
     |  
    |  |  
	
		
	
	
  | 
    
      
              |  | Plumbing Expert |  | 
 
                  
                      Sep 30, 2008, 06:57 PM
                  
                 |  |  
  
    | 
        
        
        
       
                  
        One more thing:  We drill, we don't notch. Go to HD and buy drill bit for 2" ABS pipe ( made  specifically for  drilling for  2" ABS pipes by Milwaukee - sorry, I cannot recall the exact size, but I think is something like 2 9/16".  Also you will need 1/2" chuck drill  or angle drill ).  
 I am suggesting 2 9/16" drill bit because the hole will take not only the  1 1/2" pipe but also the hub of your fitting.  Drill through double plate and continue  drilling about 3" into the joist from the bottom. Wear goggles !  It is lot of pushing - but once you get it done, you will appreciate the final effect.  You will end up with a nice, clean hole to insert your entire 45 fitting, including the hubs.
 
 Let us know how you did..
 
 Glad I was able to help...
 
 But 1/2 of the credit goes to you for the excellent visual!   :D
 |  
    |  |  
	
		
	
	
  | 
    
      
              |  | Junior Member |  | 
 
                  
                      Oct 1, 2008, 06:02 PM
                  
                 |  |  
  
    | 
        
        
        
       
                  
        Hi Milo, 
It went well!  
 
The joist was not exactly  centered over the top plate like I drew it, so that helped - the hole breaks out the side of the joist very nicely on one side and not at all on the other. - that's good!  (I nailed a 2x4 temporarily over the side of the joist so it wouldn't break out while I was drilling).
 
I ended up going right from the one street 45 into a 90 deg ell and then over about 16 inches before going up through the attic floor.  This wasn't strictly necessary, but it lines it up with a wall in the attic above that I can use to anchor the rest of the vertical run. 
 
Here are some pics:
  
Close up:
  
From below:
   
Thanks a lot for your advice, it helped a lot.  I probably would have hacked it to pieces with the sawzall - this is much better.
 
PS: You mentioned wearing eye protection while drilling which is a good idea.  I'd add that wearing good heavy gloves  is also a good idea!  If that hole saw binds up while drilling it can be murder on your knuckles!
 
Cheers, 
Roy
     |  
    |  |  
	
		
	
	
  | 
    
      
              |  | Plumbing Expert |  | 
 
                  
                      Oct 1, 2008, 06:06 PM
                  
                 |  |  
  
    | 
        
        
        
       
                  
        Thanks for the follow up. It is a nice and clean job. We like it that way. I can even see a bit of slope in that horizontal section of the vent pipe. Well done !
 |  
    |  |  
 
 
 
  
    | Question Tools | Search this Question |  
    |  |  |  
 Add your answer here.
 
Check out some similar questions!
Need for a vent line
 [ 2 Answers ]
I am adding a sink in a bathroom about 10 feet from the bath tub and will be tapping into the bath tub drain line.  Since the sink drain is a standard hight above the floor and the drain is below the floor, do I need a dedicated vent for the new sink?  Thanks.
 
Vent line
 [ 1 Answers ]
How many vent lines do I need in a bathrrom if I have a tub shower and sink. All three will tie in o a 3in line that dumps in to a sewage pump. Can I just vent the main line?and can I tie into a vent line that is being used for the plumbing that is used for some other stuff?
 
A/C vent line
 [ 1 Answers ]
I was curious if the a/c vent line is supposed to have standing water in the line. It seems to me that this line should be free of anything to include water. The problem I have is that my a/c is leaking under the drip pan and I think it is the vent line clogged up. The drain pan is not full and the...
 
Vent line
 [ 3 Answers ]
I recently bought a house that includes a well, and septic tank. Before we moved in a lot of construction work took place. They filled the bath with plaster, and other debris which ended up in the sewage drain pipes. I don't know if that has anything to do with the problem or not, but my bath on...
 
Vent line
 [ 1 Answers ]
Does a vent line have to be installed upline from a toilet, on can it be downstream?
 View more  questions
Search
 
 |