    Tub drain pipes
    I am having a bathroom renovated. After replacing the old tub, the plumber connected the drain pipe of the new tub to the old system with cast iron pipes, connecting them to the old system with screw tightening sleeves, rather than threading pipe fittings. I am concerned that this type of connection might leak after a while. Is that a common practice? I live is a concrete building (COOP) on the 12 floor, and a leak could be a BIG problem.
    Should he have simply replaced the old pipes with new ones with threaded fittings?
    Thanks
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Oct 6, 2005, 04:07 AM
    Those "sleeves" are called No-Hub Bands and I've installed entire high raise condominium drainage systems using them. That was 25 years ago and no complaints yet. Don't worry. The connection's both safe and secure. Regards, Tom
    theBigkill's Avatar
    theBigkill Posts: 43, Reputation: 1
    Junior Member
     
    #3

    Oct 6, 2005, 10:14 AM
    Speedball is right, that is a really popular and acceptable method of coupling pipe. You can find this on almost all the cast iron stacks/underground pipe installed today and if you look closely under your car you might see hose clamps(gear clamps) used there too. And if for some reason it does leak it's just a matter of tightening the band with a flat-head screw driver or a 5/16" (on most brands) ratchet or nut driver. Just make sure not to over tighten though as you could tear the clamp.
    venik's Avatar
    venik Posts: 22, Reputation: 1
    New Member
     
    #4

    Oct 6, 2005, 01:05 PM
    Thanks
    Thanks a lot, gentlemen. This makes me feel much better. However, the guy putting down the floor in the bathroom is going to pour cement on these connectors, so a leak could be very difficult to correct, which is why I worried.
    theBigkill's Avatar
    theBigkill Posts: 43, Reputation: 1
    Junior Member
     
    #5

    Oct 6, 2005, 04:58 PM
    As long as its on there tight it will be good... but
    If you're losing sleep over this and must be absolutely sure, run water down the drain for at least a continuous 5 minutes and check for leaks, and make sure the band is tight before he pours the concrete.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Leaking shower drain/pipes? [ 2 Answers ]

Hello. This looks to be a great forum! I'm glad my search pulled it up. I have a 2nd story shower leak. Directly below the shower is the laundry room and has the furnace ducts/furnace directly below. I've already decided I'll have to remove the ducts and open the ceiling to see what is...

Running Drain pipes through 2 x 8 floor joists. [ 1 Answers ]

I am doing an addition and need to move my 3" drain pipes. My question is can Holes be cut into the floor joists (2 x 8). to accept the 3" pipes. The pipes are for the upstairs bathrooms.

New faucet drain tailpiece does not align with existing pipes [ 1 Answers ]

I simply installed a new faucet & drain pipe for my existing bathroom sink, but now the drain tailpiece does not align with the existing pipes. This doesn't make sense to me, since the drain tailpiece is a straight pipe, but whatever. Do I have to replace the trap, etc. now to make everything...

Do washer drain pipes need a sewer trap? [ 1 Answers ]

My hubby has moved our washer and dryer and it works - mostly. We have some soapy foam coming out of the top of the drain pipe. He raised the pipe and we have less, but still some soapy foam. I wish I had checked your forum earlier as I've learned that washers drain with a lot of pressure. ...

Cast iron or PVC waste/drain pipes? [ 5 Answers ]

Hi everyone. I'm in the middle of a major remodel to my 1947 home, including adding a second story. We're trying to do everything top-notch, which leads me to the experts here. Here's my question: For the waste/drain pipes, I know we want to use cast iron in the drops between the floors (for...


View more questions Search