    Snowsun Posts: 4, Reputation: 1
    New Member
     
    #1

    Sep 29, 2009, 11:46 PM
    Sbmersible pump and retention tank kick on too often
    I have just installed a new submersible pump and a retention tank. The hose between the pump and the tank has to be emptied automatically to prevent the system from freezing during winter. So every time the pump kicks on, the air in the hose will be pumped in the tank. The plumber suggests a 40 gallon rentention tank with no membrane but with a vacuum breaker installed at the half high of the tank to evacuate the excess of air. Once installed, the system works perfectly. The pressure switch is set to 30-50 psi. However, every time the toilet is flushed, the pump kicks on. In another word, only 3 to 4 gallons of water drawn will activated the pump. This is too little compared to a tank with a capacity of 40 gallons.
    Is there any way the situation can be improved or should I use another type of tank, such as a bladder tank or change a 25-50 psi switch ?
    Thanks.
    Snowsun
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Sep 30, 2009, 04:41 AM
    I'm no pump guy and I just proved it in another thread but wouldn't bleeding the air out of the pressure tank take away the air cushion and force the pump to kick on every time s draw was made? Why not treat this like a regular pressure tank with no vacuum breaker and a valve on top to relieve the air lock when you drain it for the wenter. Why evacuate any air at all when you turn the system back on. That air will compress and send pressure out without the pump running each time you flush or make a draw. If I've missed something here please let me know. Regards, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Heat pump won't kick on [ 1 Answers ]

I have a Carrier heat pump 2 years old and the AC etc. won't come on... The thermostat shows temps and when you put it on cool etc. nothing happens... I tried to see if the fan setting would work but it doesn't... I've also tried the heat, Eheat and Auto settings... The thermostat says each is on...

Well pump tank [ 6 Answers ]

I have a new pump tank. When I turn it on it stays on for about 3 seconds and the water comes out , but then stops and then a few seconds later the pressure goes back up and the water comes out again. It doesn't feel like there is water in the tank. What should I do and how can I fix the problem...

Well pump or tank [ 7 Answers ]

I am having problem with my pump or pressure tank. I can use water by pressure tank but not other side of yard. No sound no water…nothing. My tanks pressure switch is on all the time, pump is working? Or sound working (mortar is running-sound like). When I use water by the tank, water pressure...

New well tank and pump [ 26 Answers ]

We have installed a new well pump and tank the problem we are having is this The water pumps but the pump runs kind of like the tanks not filling up what would cause the tank not to fill thanks

Air in Well Pump Tank [ 3 Answers ]

For quite some time I've noticed my well pump is full of air. Originally you could see condensation on the lower half of the tank and when you knock on the tank housing you could tell there was water in the lower half and air in the top half. For the last couple of years when you knock on the tank...


View more questions Search