    The pump will not stop and the gauge remain/stays at 35, it will not reach to 40, why
    I replace the gauge and pressure switch which was already set to 20 40 psi, I set also the tank air to 18 psi, when I power on the pump, it will not cut off and the gauge stays at 35, when I manually off the pump, it will not goes down, It means no leak in the line. Why the pressure will not reach to 40?
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    Aug 26, 2015, 05:44 PM
    This seems to me to be the most common well complaint we get, and in some ways the most difficult to diagnose from a distance. Basically, the pump will not get up to cut off pressure. Some possible answers are: 1. A leak in the wellpipe, especially if the pump is in the well. 2. A drop in the water table which makes it difficult for the pump to get up to 40 psi. 3. Pump beginning to fail.
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #3

    Aug 27, 2015, 04:33 AM
    Agree with John.
    What was the reason for replacing the old switch and gauge?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

New convertible jet pump won't reach pressure [ 1 Answers ]

I installed a new convertible jet pump in my basement today. It's the type with two pipes. It is the same type/HP(3/4)as the one I had before. After installation was complete I primed the pump. I took the top cap off, filled it with water, replaced cap and powered the pump. It took many tries but...

How to stop child support when children reach proper age [ 4 Answers ]

I live in Indiana, my check is garnished for child support all my kids are of age and out of college, how can I stop payments?

Water pump turns off pressure contacts remain closed [ 10 Answers ]

I was first alerted to a problem when no water was available at spigots. I checked the pressure gauge which had 0 pressure. Iturned off power to the pumping system. I looked at the pressure control switch to find that the points were in the cosed position. I turned the power back on and could tell...

Submersible Well Pump, won't Reach Cut-out [ 3 Answers ]

I have a 100' well with submersible pump, approx 15 years old. The other night I heard it running for an extended period and found it was about 5 psi under cutout (60) but not increasing. After turning the pump off and waiting several hours this condition remained. Due to neccesity I lowered the...

Oil gauge stays "buried" for 5-10 minutes after starting [ 2 Answers ]

2002 Ford Explorer. Oil level is good. When I start my car, my oil gauge stays buried all the way to the bottom for the first 5-10 minutes of driving. While it's buried, the "check gauge" light is lit. Generally the gauge "pops up" to where it's supposed to be after 5-10 minutes and the...


View more questions Search