Ask Experts Questions for FREE Help !
Ask
    spintly's Avatar
    spintly Posts: 3, Reputation: 1
    New Member
     
    #1

    Jun 4, 2007, 05:34 AM
    Pressure relief switch
    Hello,

    What are the steps to replace a schedule D pressure relief switch. My old switch has a manual override lever on it that I think manually restores power to the switch. I was told that I need to drain the tank of all water and turn off the power to the switch. I also heard that I need have 28 pounds of air in my holding tank if I am running a 30/50 switch.

    Thanks
    spintly's Avatar
    spintly Posts: 3, Reputation: 1
    New Member
     
    #2

    Jun 4, 2007, 06:08 AM
    Respoding to my original post. The pressure relief swith is a square D, not a schedule D switch.

    Thanks
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Jun 4, 2007, 06:31 AM
    To replace your pump control switch shut the power off to the pump and bleed the pressure down,(no need to drain the tank just open a faucet) and replace with a similar unit.
    ". I also heard that I need have 28 pounds of air in my holding tank if I am running a 30/50 switch."

    The correct setting for a bladder tank is 2 pounds under the cut in point so 28PSI would be right for a 30/50 control box.
    Good luck, Tom
    spintly's Avatar
    spintly Posts: 3, Reputation: 1
    New Member
     
    #4

    Jun 4, 2007, 11:02 AM
    I installed my pump control switch. It is working well now. Thanks for your help.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Surging water pressure & leaking water heater relief valve [ 19 Answers ]

Just recently the pressure of our water in the house surges when we turn a faucet on, and the city water company verified that our pressure in the house when we open a faucet is higher than the pressure in the lines in the street, and after the water runs is at a normal pressure (meaning their...

Roof air pressure relief [ 1 Answers ]

I will be building a 35' x 70' wood framed metal structure soon. I plan on sheeting in the roof only this year and the walls next year. My concern is that I'm building in a very windy area in Kansas and I'm worried about the roof blowing off. I plan on using hurricane straps, but I was...

Pressure relief switch [ 15 Answers ]

I recently installed a new pressure relief switch onto the pressure system in our home. The switch works great and there is pressure going to the tank, but there is no pressure coming through the lines. :confused:

Pressure relief valve [ 11 Answers ]

Hi, I have a State Select brand water heater (40 gallon) which is about 4-5 years old. It recently has begun to leak from the pressure relief valve, and is leaking a lot:( , especially after taking a shower... Is this a simple fix of replacing the valve or something more serious? Any and all...

Water Heater Pressure Relief [ 3 Answers ]

My water heater pressure relief valve is pouring water out of the valve. Do I have a problem with the tank or do I need to turn the temperature down on the heater. More background information: We went on vacation and turned off the water heater and the water to the house. When we returned, we...