    Need PEX sizing for installation
    I have been reading the "RePiping with Pex" thread and have some questions..
    I found the link to the PEX pdf but will read tonight..

    We have an old house that has under the floor coper, the house has developed to leaks in less than
    A year.
    The plumber suggested replacing all the water lines with PEX and abandoning the
    Under Slab

    My Brother in Law are doing the Tear out..

    - Location Oklahoma City (about 1700 sq ft)
    - We are not doing a "Home Run" or "Manifold due to space requirements
    - 2 Full Baths
    - Kitchen w /Dishwasher
    - 2 outdoor Faucets
    - 1 Refrigerator supply
    - Attic has about 30" of blown insulation.
    - Incoming Supply is a in Bathroom under vanity. (think it is 7/8"
    - Hot Water Tank is in Garage - about 30' away

    My questions
    What size of PEX should I use

    We are looking at using 1/2' everywhere
    Except using 3/4 from Supply to Hot Water Tank
    Will this work

    I can provide ASCII art if needed.

    Much thanks

    Rk...
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    Feb 17, 2009, 08:40 PM

    I would run it as follows:

    Cold water: 1" main run, distribute to each plumbing fixture with 1/2" branches. But Water heater 3/4" supply. Shower 3/4" optional. Hose valves 3/4". Washer 3/4". You can go to smaller diameters in main run as you pass w/h , w/m , and 1st bath.

    Hot water: Start with 3/4" and tee off to each fixture with 1/2". Once you pass washer and 1st bath, you can reduce to 1/2". Insulate hot water runs.
    roundkat's Avatar
    roundkat Posts: 2, Reputation: 1
    New Member
     
    #3

    Feb 18, 2009, 04:58 PM
    As we got into it we found that we could abandon the 3/4" under the slab
    and reuse the copper "branch" which is 1/2" copper.
    We only have to run 5 PEX lines of any distance.

    Much Thanks,
    Rk

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Wire sizing and conduit sizing [ 8 Answers ]

I am looking for confirmation on some of the info I have found and answers to a few missing pieces. This is regarding wire size and conduit size for service conductors from the meter to the breaker panel (about 30 ft away). Wire Size: 125A service needs #2 copper or 1/0 aluminum -- #6 copper...

Sizing of UPS [ 1 Answers ]

Dual UPS should be used to drive Server and networking equipment load. Both UPS should share load equally in normal operation. But during maintenance or any break-down of one UPS other UPS should be able to take total load. Server will remain on always. What should be rating of single UPS in terms...

Sizing of UPS [ 2 Answers ]

Hi, If I have 300 computors each with a load of 400watts and I want to make provision for UPS back-up, what size UPS do I cater for? I have 3 phase 400VAC available.:rolleyes:

Bow Sizing [ 2 Answers ]

How does one determine what size bow to buy? I have noticed many lengths and draw distances. I don't want to spend a lot of money on a bow to find out it is not comfortable to use.

Sizing the kva for TRANSFORMERS [ 2 Answers ]

What Would Be The Right Size Transformer. Power Coming In Would Be Single Phase 480 Output Is 120v , About 4.2a I Figure About 1kva Would Be Plenty


View more questions Search