Ask Experts Questions for FREE Help !
Ask
    Diesel984's Avatar
    Diesel984 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jul 15, 2010, 08:54 PM
    Pacific Hydrostar Shallow Well Jet Pump issues...
    Good Evening to all of you in Cyberspace! I want to see if you can lend me a couple ideas on why my pump isn't working.

    I bought the 1 Horse Jet pump from Harbor Freight, And have everything set accordingly. For our well, the Top of the water line is at about 14' below where I've got the pump, so Lift height shouldn't be a problem at all. The Piping I used is Schedule 40 1" PVC. I've looked at all my connections and have not seen any where they are loose or where water could escape.

    I've also primed the pump according to what the manual says (and inflated the air bladder inside the tank to 29PSI per the specifications on the unit itself) And it won't pull up any water at all...

    I don't understand the dynamics of this pump and I don't get why it's not pulling any water either. The other problem I've seen is that the pressure gauge on the impeller housing doesn't move off the 0 mark...

    Do any of you have any thoughts on what COULD be causing this? Or do I just need to take this pump back to them and get a new one?

    LMK what you think!
    Nate
    tow100's Avatar
    tow100 Posts: 1, Reputation: 1
    New Member
     
    #2

    Jul 15, 2012, 06:18 AM
    Do you have a check valve at the end of the input line. I have one pulling
    About 6 feet height over a 35 foot length and I have a check valve at the end.

    In the spring it takes quite a while to get the pump primed, but once primed
    It holds the pressure. 14' is a long length w/o a check valve.

    Try it check valves are cheap.
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #3

    Jul 15, 2012, 06:28 AM
    It would seem you have a footvalve at the end of the wellpipe. I say that because you say you primed the pump. So you removed the prime port on the pump and poured in water until it overflowed? And before you replaced the port, did you make sure the level of water in the pump stayed level?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Do I need a Shallow well pump ? [ 9 Answers ]

:cool: Hi, I just bought a cabin that has a spring on the property up above the house at an entry elevation that is maybe 7-10' above the roof line. My spring flows into a shallow holding well then flows through 1" sprinkler line (Black plastic hose) The water must flow constantly because...

Shallow well pump [ 1 Answers ]

I can't seem to get my wellsaver tank to fill to hold pressur .I have a shallow well pump.

Shallow-well Pump Issues. [ 4 Answers ]

Hello. I will try to describe our problem as best I can: Yesterday we ran our well dry and didn't realize there was no water coming out of the hose for maybe an hour? All this time the pump was running. The well is now full of water. We checked the foot valve on the bottom of the water intake...

Shallow well jet pump [ 7 Answers ]

I replaced foot valve and pressure switch but pump will not build pressure and pump out water

Shallow well pump [ 1 Answers ]

It will build pressure but as soon as it shuts off at 38lbs. It drops to 18lbs. In about 1min