Ask Experts Questions for FREE Help !
Ask
    Brother Tim's Avatar
    Brother Tim Posts: 4, Reputation: 1
    New Member
     
    #1

    Mar 2, 2007, 11:33 AM
    Moved Washer upstairs, Q about venting
    I wish I had discovered this forum earlier...

    I moved my washer/dryer upstairs and had no trouble doing the plumbing, I thought :-)

    It is working fine so far, but after reading some posts it seems I may should have vented the washer drain.

    Currently it is on a 40" stack pipe. The P-trap is below the floor, and the drain line tee's into the sink's 1.5" drain eight feet from the washer's P-trap. Then the sink drain empties into a 6" drain about 12 feet later.

    So far no problems... I have not yet done the drywall behind the washer completely. Should I add a Studer AAV? The washer drain is not a tight fit, so I assume some natural venting is occurring, right?

    Thanks in advance!
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Mar 2, 2007, 12:22 PM
    That non-tight fit isn't going to help as much as you think. The vent should be after thetrap. A stuer vent would be a good option. Are you saying the sink drain isn't vented either? If it has a trap it should have a vent.
    Brother Tim's Avatar
    Brother Tim Posts: 4, Reputation: 1
    New Member
     
    #3

    Mar 2, 2007, 01:51 PM
    The sink is vented... all seems to be working fine... I was just wandering if the washer drain had to be vented or if the vent from the sink was OK. Thanks.
    doug238's Avatar
    doug238 Posts: 1,560, Reputation: 62
    Ultra Member
     
    #4

    Mar 2, 2007, 01:56 PM
    If the washing machine trap is not vented and not on a 3" trunk line then the flow of water could pull the trap dry.
    Brother Tim's Avatar
    Brother Tim Posts: 4, Reputation: 1
    New Member
     
    #5

    Mar 7, 2007, 07:41 AM
    Thanks Doug... that I understand (now). I could not understand why the vent went after the trap... duh... now I get it. I have had no problems doing 4 loads a day for 2 weeks now. SO I think the vent from the sink is sufficient, but if I have a problem I will have to put in a second trap + AAV after it or cut the flooring to access it. (The drywall is nearly finished in the basement!)

    Thanks everyone!

    I am a photographer. Guess I should go over some posts related to that and return the favor ;-)

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Ex has moved on... almost? [ 11 Answers ]

Here's the long story short.. after being together for almost 2 years my boyfriend broke up with me 4 months ago at the beginning of junior year of high school saying he doesn't want to be in a relationship right now and needs a break. Now I realize we're still young and there's other people out...

Basement toilet bubbles when upstairs toilet is flushed and washer drains. [ 1 Answers ]

Hi, Just recently (last few days) my toilet in the basement bathroom has begun to bubble. This is caused when one of the upstairs toilets (directly above it) flushes but not another one upstairs. It also bubbles quite rapidly when the clothes washer drains. The washer is located in the...

Washer moved now it overflows at the drain [ 2 Answers ]

Hello, I just recently moved and installed a washer into a new location. I washed a load in the washer and the drain backed up. I had another washer in the same location, but didn't have any drain problems. Is it my washer, washer hose or maybe my drain is clogged?:confused:

Venting for a washer. [ 3 Answers ]

I would like to add a washer hook-up in a utility room that I have. It is on the 1st floor of a 2 story home. Directly above it is a bathroom, so I have hot and cold water lines in the wall. As well as two waste pipes (a 3" from the toilet and a 2" from the sink/shower). I am assuming it is a...


View more questions Search