    Maximum vertical fall distance shower drain to p-trap below it.
    What is the maximum vertical fall distance between the shower drain and the 2 inch trap just below it?
    :)
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    May 13, 2009, 02:48 AM
    Hi Tom...

    The maximum length the tailpiece from fixture to ptrap in my area is 24"... anything longer and the velocity of the water could SIPHON the ptrap and cause sewer gasses to enter the home...

    Let me know if you need more info...

    MARK

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Maximum distance from sink to p trap [ 5 Answers ]

Hi, What should the maximum distance be from the bottom of the sink to the p trap. If I stay within this distance is there any problem installing a p trap below floor level? I want to do this because of space limitations when installing a pedestal type sink. Thanks, Tom

Vertical Kitchen Sink Drain Distance from Wall [ 4 Answers ]

I am putting in new countertops with deeper sinks. I want to change my drain from a horizontal to a vertical through the bottom of the cabinet. What is the recommended distance from the wall to the center of the vertical drain? I have plenty of room to do this and want to make the change before...

Shower drain trap [ 1 Answers ]

I have removed a bathtub and I'm replacing with a shower. The shower tile installer asked that the new drain be placed in the middle of the floor. There is a heating duct that prevents placing the drain trap directly under the drain. Is there a problem if I run an 8" section of drain pipe to a...

Vertical distance to trap [ 3 Answers ]

I'm installing a basement shower. When the house was built 2 years ago, it was pre-roughed, with a plastic cover over the hole where the drain will be. I was surprised after opening up and removing some dirt that the 2" horizontal drain line is so deep - it is 12-1/4 inches from the top of the...


View more questions Search