    Jet well water pump will not shut off
    Have a shallow dug well. The well ran completely dry. Before I realized it, used all of the water in system including hot water tank.Finally got water in well -2 months later.Had to prime pump to get water. Couldn't gt the primer plug out so had to take hose off the pressure tank to prime. Now pump will not stop running and it takes least 30 minutes or more for pressure to build up to 40. If I let it run, it will continue to go up----very slowly--to 50-55 but this takes an hour.
    I shut it off and I can flush the toilet a couple of times and use a little water before the pressure drops down to 10 or less and can no longer get water. I replaced the switch and the tube from the switch to thepressure gauge . Same thing. Checked the valve on top of tank and air comes out... no water.
    This is an old pump.
    jlisenbe's Avatar
    jlisenbe Posts: 5,019, Reputation: 157
    Uber Member
     
    #2

    Nov 16, 2010, 10:29 AM

    How many pipes go into the well, one or two? If it's one, then be aware that your pump becomes inefficient at around 20' and won't pump at all at much past 25'.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

1/2/HP craftsman jet shalllow well pump only pumps to 25 psi & won't shut off. [ 3 Answers ]

My pump pumps to about 25 psi & won't get any higher. Holds it's prime. PSI switch is per set to 40/60 & new. Air in tank checked around 25 when -0- psi on gage. Pump is maybe 3 years old. Thanks

Flotec 3/4 HP Jet Pump where it continues to cycle and won't shut off. [ 6 Answers ]

It had been working OK except for low water pressure. I've tried everything to get it working again including switching out the tank (the tank has 27 psi pressure) and putting in a new pipe with a new foot valve. I still can't get there pump to turn off. I have to turn the breaker off and then I...

Jet pump will not shut off and pressure does not pass 40 psi [ 1 Answers ]

I have a Myers jet pump with 2 lines coming out. The pump sits approx 20 feet high from the lake source with a 70 foot run to the lake. Pump kicks in at 20 and rises to 40-42 and will not shut off unless I manually do it and the pressure will hold constant at 40 until the water demand brings it...

Bad hose water pressure, jet pump, missing well [ 6 Answers ]

OK, so my friends tell me that this would only happen to me... we can't find our well - which is or first problem. How does one lose a well you may ask, I don't know but the county (Montgomery Co, MD) records do not go back far enough on our house (built in 1959). We have pump in the basement...

Trouble getting water, jet pump system [ 8 Answers ]

Hi, I have a jet pump system, had trouble getting water, thought it was my pump so I got a larger hp pump( 1hp) still no luck, sometimes I can't get enough water to brush my teeth, the water stops and the pump won't shut off, I have to turn off the breaker to the pump and leave it for a while ,...


View more questions Search