Ask Experts Questions for FREE Help !
Ask
    higsb's Avatar
    higsb Posts: 1, Reputation: 1
    New Member
     
    #1

    May 31, 2013, 10:17 AM
    Install a P Trap
    I purchased a bath room vanity from IKEA that has limited space for installing piping including a P trap! I did get it installed without the trap however, there is a sewer smell coming from the drain in the vanity. I know it needs a p trap but at the time I could not figure out how to get a trap for the limited space inside the vanity! This vanity has two draws that allows for a 4 and 3/8" space between the back of the draws to the wall. I cut an opening on the wall to give me enough space to attach the drain pipe from the sink but no room for a P trap. I don't want to cut any part of the vanity draws to accommodate a trap, and have search for a small but adequate P Trap to fit in the space - no luck. The space inside the wall is 3 and 7/16" deep. Any suggestions would be greatly appreciated!
    Attached Images
     
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    May 31, 2013, 12:06 PM
    Any suggestions would be greatly appreciated!
    First thing I would do would be to move that vanity brace down to fit under the stop valves and the trap. Then assess the situation for the trap.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #3

    May 31, 2013, 12:44 PM
    Hi Higsb

    My guess is that you have a drawer there and you haven't thought about cutting it... is that correct? If so, then I would suggest that you remove the drawer for now, install a PTRAP correctly and then cut a notch out of the back of the drawer (see image)... should not need to cut the bottom of the drawer. That should allow the drawer to slide in and out without hitting the new PTRAP. A notch like this will NOT affect the integrity of the drawer as long as you don't plan on standing on it... ;)

    Finally, do NOT put this off for too long... sewer gasses are very unhealthy!

    Mark
    Attached Images
     

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Can you Install a house trap yourself? [ 4 Answers ]

I just had a plumber come out and they told me that my house trap is rusted/clogged and has tree roots in it. Their recommendation is to replace it (I totally agree) I'm pretty sure that the code in Allegheny county, PA says that you have to keep the trap. Unfortunately, the Roto-Rooter guy said...

I need to install a p-trap for above/inground pool [ 1 Answers ]

I'm having a partial inground/above ground pool installed with vinyl lining. I need to install a p-trap in the clean-out thingee in case I ever have to drain it with a hose. How can I install the p-trap?

Basement Bath P-Trap Install Details [ 1 Answers ]

I am preparing to install a bath tub in a new basement bath. The groundwork is done, dirt's back in the hole and my next step is to re-pour the concrete. I know I need to leave a box around the tub drain and vent connections for hook-up later and have a few questions on the details. 1. How...

Install dishwasher on second trap? [ 6 Answers ]

We are in the midst of installing a new kitchen. Our old kitchen has the standard double sink and adjoining dishwasher all going to a single p-trap in the sink cabinet. One of the things that really bothered me with this arrangement was the GE dishwasher drain noise that came up through the...

Can I install an inline trap between shower and septic? [ 1 Answers ]

Before you jump all over me about code violations, let me preface this by explaining that this is a house in the Caribbean and what plumbing there is would never pass code in the US or elsewhere (and don't ask me about the electric!). The shower is installed without a P-trap below the drain. It...


View more questions Search