    How can I get my water heater up to code for fha? They say I have to have a extrinal
    How can I get my water heater up to fha standards? The guy that came out said that I have to have it externally piped out. My house is cinder block and cement floors.
    dontknownuthin's Avatar
    dontknownuthin Posts: 2,910, Reputation: 751
    Ultra Member
     
    #2

    Dec 13, 2012, 12:32 PM
    If it's a gas water heater it has to be vented so that it does not release carbon monoxide into your home. Some units have a built in electric fan unit. You should have a plumber come look at the water heater you have and to determine if it can be properly vented, and if not, to install a new one that meets the code. Because you're dealing with gas and plumbing, I don't know that I'd try this as an amateur.
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #3

    Dec 13, 2012, 06:11 PM
    Need to know more about the heater? Its gas I assume and how is it currently vented? Don is on the right track
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Dec 13, 2012, 06:32 PM
    FHA requires that the water heater have its temperature and pressure relief valve (T&P valve) piped to a code approved properly vented and trapped drain or it can also be piped exterior to the building. My guess is that we are talking about piping the T&P valve exterior to the building.

    Every code differs as we all know, so would like to know what state we are talking about and would like Tinie to ask "the guy that came out" and ask for specifics here.

    Mark
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #5

    Dec 13, 2012, 08:12 PM
    Assuming it's the T&P, most block houses run the pipe through a void section of the block. A 1" hammer drill bit is perfect and then you fill the balance of the hole with cement or stucco patch.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Monitor heater error code 13, how do I trouble shoot and fix heater? [ 3 Answers ]

My monitor heater is 3 years old and has never had a problem since installed. It is now giving an E 13 error code. Where should I start when trouble shooting? I have 2 other monitors that come off the same fuel supply line, this is the first in the series. Any idea where to start?

No or very slow hot water from gas water heater, heater makes lot of sounds [ 1 Answers ]

There is problem with our hot water system, not getting hot water while as cold water is OK. Starting hot water there is lot of explosion sort of sounds from water cylinder and hot water will start dribbling and stops after some time.

Water heater leak (cold side only) where the nipple meets the water heater [ 9 Answers ]

I just bought a water heater and completely installed it. When I turned on the water supply, a very very very slow drip can be observed where the cold water nipple screws into the water heater. I shut off the water, relieved the pressure and unscrewed the nipple. I then re-apply the teflon tape...

GE water heater ECO Failure code [ 0 Answers ]

GG40T06PVJ water heater gas valve LED error code. What does this mean?

Water heater code [ 1 Answers ]

What's the code on water heater replacement, concerning the metal tray under the heater? My heater is installed in an attached storage room, on a concrete floor that slopes away from the house. Does Code require a tray?


View more questions Search