    drain sizing
    Is 3" pvc piping too big for a drain which will tie in an existing 2" pvc drain (bathtub, sink, kitchen sink/no dishwasher 1st floor apt) with an new 2" drain in cellar for washing machine and utilty sink. 3" pipe would replace 11' declining (1" per ft)run along cellar wall of exisiting 2" pvc pipe which bends and drops 5" to enter the sewer drain at floor level(yes, a back check valve is installed as well as vent pipe and cleanout) 2" pipe seems too small for the additional volume of water but 2.5" is probably only available at supply houses. The difference of only 1/2" in the size of the pipe seems negligible.

    pvc drain for tub and sinks only was rerouted from main stack in order to add a necessary structural element (2x 8" joist) 1st floor bathroom floor below inside wall. Which was never installed. Toilet drain remained unchanged and continues to drain into the main stack pipe.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Aug 24, 2011, 04:39 PM
    Is 3" pvc piping too big for a drain which will tie in an existing 2" pvc drain
    why would you want to choke down to 2" from 3"? Should be the other way around. Why can't you cut out the 2" and run 3" all the way?
    sink/no dishwasher 1st floor apt) with an new 2" drain in cellar for washing machine and utilty sink. 3" pipe would replace 11' declining (1" per ft)
    You have a drainage pip[e that slopes 11" in 11'? Way,way too much fall. Should be 1/4" to the foot giving you a 2 3/4" drop.
    There's a problem with too much slope. Too little and won't get a good flow. Too much and the liquid runs out so fast to leaves any solids behind.
    Bottom line. I would run 3" all the way. Good luck, Tom
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #3

    Aug 24, 2011, 05:46 PM
    Tom,

    I think Egret wants to connect one 2" drain carrying bathtub, sink, kitchen sink/no dishwasher (1st floor apt.) with another 2" drain in the cellar for washing machine and utilty sink and increase to 3" pipe to replace older 2"pipe, right?

    If so, it doesn't change much as the advice you gave is still the same. Increase to 3" and improve the slope of piping to 1/4"pitch per foot with an offset to drop the piping into the sewer drain at floor level... ;) As you noted Egret, 2.5" size is not common and is not used in most cases residentially or commercially.

    My only other thought is to install full-size test tee cleanouts at each 2" branch line just before combining into the 3" pipe.

    Thanks...

    Mark

    PS: By the way, if I haven't said it, it's real nice to see you up and posting again! I swear you answered every question on the plumbing page the other day...all speedball, speedball, speedball, speedball...:) Nice to see that again!!
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Aug 24, 2011, 06:01 PM
    Thanks Mark! It's good to be back in the saddle again.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Wire sizing and conduit sizing [ 8 Answers ]

I am looking for confirmation on some of the info I have found and answers to a few missing pieces. This is regarding wire size and conduit size for service conductors from the meter to the breaker panel (about 30 ft away). Wire Size: 125A service needs #2 copper or 1/0 aluminum -- #6 copper...

Shower Drain Sizing [ 1 Answers ]

What is the calculation to size a proper shower drain ? Multiple shower components are being used.

Drain Line Sizing [ 11 Answers ]

I am putting in a new bathroom which is about 50' from my main drain stack. My question is: do I need to use 3" or 4" pipe for the horizontal drain line? Right now, draining into this will be a clothes washer, tub/shower, vanity and toilet. Eventually, I may drain a kitchen, and/or another...


View more questions Search