    CPVC threaded coupling to Brass nipple is leaking
    I just installed a new sink in my garage using CPVC for the plumbing run. Never used CPVC before. Where I came through the wall, I used a CPVC female threaded fitting with ears on it to fasten to the wall stud. I then screwed a 4" brass nipple to it with teflon tape and attached the valve to the other end with teflon tape as before. I now notice a slight weeping or sweating leak at the CPVC fitting. There is a rubber washer inside the CPVC fitting, so now I'm wondering if I just didn't screw it down tight enough. How tight do I screw the brass nipple into this CPVC fitting? Am I not supposed to use teflon tape since there is a washer inside the fitting? I'm a bit concerned that if I really reef the nipple down tight, it might crack the CPVC fitting itself.
    Thanks for your help!
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Mar 14, 2008, 04:17 AM
    And you should be concerned about cracking the fitting FFF. Good for you.

    I would take apart, and pipe dope the brass nipple and re-install using the rubber washer only. Or just wrap teflon 2-3 times clockwise.. ok?

    Does your fitting look similar to the fitting in my pic. (except yours has ears)? I think with this fitting you need to feel the threads on the nipple bottom out into the rubber washer... but it is going to be scary... no choice though.. OR could remove the washer and use 7-8 wraps of tefon and re-install that... but still need to tighten pretty good. Hold against yourself with pliers as you tighten the brass nipple in and you should be fine.

    Hope that helped... Good luck... Mark
    Attached Images
     
    iamgrowler's Avatar
    iamgrowler Posts: 1,421, Reputation: 110
    Ultra Member
     
    #3

    Mar 14, 2008, 07:17 AM
    Quote Originally Posted by funfamilyfare
    I used a CPVC female threaded fitting with ears on it to fasten to the wall stud. I then screwed a 4" brass nipple to it with teflon tape and attached the valve to the other end with teflon tape as before. I now notice a slight weeping or sweating leak at the CPVC fitting.
    Using metallic threaded fittings on plastic female fittings is just asking for trouble, particularly on the hot side of the system.

    Expansion and contraction within the system will eventually crack the female fitting.

    If you want to make a proper plastic/metallic transition, then you should use an approved brass to CPVC drop ear 90.
    Attached Images
     
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #4

    Mar 14, 2008, 08:06 AM
    FFF:

    Growler's right on... If you can get your drop ear fitting off the studs, I would change over to the fitting he showed you. A better job in the end.. for sure!

    Let us know what you decide.
    funfamilyfare's Avatar
    funfamilyfare Posts: 11, Reputation: 1
    New Member
     
    #5

    Mar 17, 2008, 11:44 AM
    Thanks all!
    I figured the risk wasn't worth it, so I opened up the walls and replaced each with the SharkBite brass connectors. Everything works great now and I can sleep nights.
    Again thanks for the advice!
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #6

    Mar 17, 2008, 01:29 PM
    Can't beat the sharkbite! Thanks for update. Take care now... Mark

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Copper to cpvc threaded connections [ 2 Answers ]

Hi, Can I connect cpvc threaded pipe adapters directly to corresponding male or female threaded copper adapters, and, using suitable pipe dope, get good reliable joints? I know there are threaded copper-to-glue cpvc conversion connectors available, but I have on hand a number of copper and cpvc...

Teflon tape on threaded brass connections [ 1 Answers ]

I noticed on shower faucets that threaded brass connections were not teflon taped. Should teflon tape be used on threaded brass connections ?

New shower valve has threaded unions, old one has non-threaded soldered supply lines [ 2 Answers ]

I bought a new bath/shower two handle 8" spaced valve unit. It has threaded supply unions, but the supply lines are not threaded. What do I need to convert the lines? Can I install stop valve and flexible lines to the threaded valve body hot/cold connections?

Tub faucet leaking from back. Nipple length wrong? [ 6 Answers ]

We just had new copper pipes installed and are trying to attach our new tub faucet (Delta Universal Trim.) When we attach the faucet so that its flush to the wall, water leaks from the back. When we pull it away from the wall about 1/4", the leak stops. All we did to install it was slip the...

Leaking threaded pipe [ 1 Answers ]

Is there anything I can use to stop a leak at a threaded nipple pipe? Its on the mainfold of my boiler, and of course, it's the most inner pipe on the return line of a multi-zone manifold. I don't want to disassemble the whole manifold if I don't have to. The pipe is about 6" long on the...


View more questions Search