    Cast Iron Kitchen Stack
    I'm replacing the drain stack in my kitchen. I have the wallboard removed and exposed is the cast iron stack from the basement. At the top of that stack about 19" above floor level (inside the wall) is the connector or hub that receives a vertical “T”. Entering the “T” horizontally was the old P trap and vertically at the top of the "T" is the vent ( galvanized pipe).
    I'd like to replace that stack inside the kitchen wall to somewhere above the basement floor. I can connect new PVC inside the kitchen wall and down into the basement to that cast iron with the shielded connectors that I've read about here.
    I know that the sink tailpieces and P traps will be 1 ½”, I'm not sure what sizes of PVC I should use elsewhere. The current cast iron stack is 2 1/2 " O.D (4 1/4" O.D. hub). That hub connects on top to the 2/14" O.D. " O.D. " (3 3/4" O.D. hub) that received the old P trap and galvanized vent pipe.
    Also, I'd like to know if I should install a vertical clean-out where I connect just above the basement floor while I'm at it.
    Hope that explains what I have here. Thanks in advance.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Feb 13, 2010, 11:18 AM

    I know that the sink tailpieces and P traps will be 1 ½”, I'm not sure what sizes of PVC I should use elsewhere.
    Go 2" all the wy from where you converted to PVC. The 2" "P" trap will have a gasket to attach the sink tailpiece to.
    Cleanouts are always good. You just can't have too many. Good luck, Tom
    Specklebird's Avatar
    Specklebird Posts: 2, Reputation: 1
    New Member
     
    #3

    Feb 13, 2010, 11:54 AM
    Thanks for the advise speedball. I thought that 2" was the I.D size of the cast iron stack, I just hadn't cut it yet to confirm.
    I'll have to find an adapter to fit the 1 7/8 O.D. galvanized vent into a new 2" PVC double sanitary T as I think I have to put double traps under the sink (county code).
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Feb 13, 2010, 12:06 PM
    Quote Originally Posted by Specklebird View Post
    Thanks for the advise speedball. I thought that 2" was the I.D size of the cast iron stack, I just hadn't cut it yet to confirm.
    I'll have to find an adapter to fit the 1 7/8 O.D. galvanized vent into a new 2" PVC double sanitary T as I think I have to put double traps under the sink (county code).
    Use a 2 X1 1/2" slip to a 1 1/2" female threaded reducer and simply thread the galvanized in one end and glue the other end on to a short piece of PVC that will be coming out of a 2" sanitary tee that you will use in place of a double san tee. Once stubbed out of the wall install a wye and tun your traps off that. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Cast Iron main stack [ 1 Answers ]

I have a 50 year old house, and the drain lines are 1-1/2" galvanized steel with cast iron elbows and tees. All drain lines run to a cast iron main stack. I need to replace one of the 1-1/2" galvanized steel pipes that enters a 3" leg of a "Y" that looks like a sanitary tee in the main stack. ...

Split Cast Iron Vent Stack [ 5 Answers ]

Tom, Mark, Milo, Anyone, What, other than age, would cause a 3" CI stack/vent to split longitudinally? About a 12" crack in a 4' section of pipe, about 12" from one end?

Cast Iron Vent Stack [ 2 Answers ]

I have just purchased a 1950's rental property with a cast iron vent stack. The insurance co. wants me to replace it as they are prone to leaking in older homes. The job seems fairly straight forward, but do you have to replace the elbow/cleanout at the bottom that is cemented into the basement...

Cast iron soil stack to pvc [ 15 Answers ]

the plumbing in our house is from 1936. We noticed a large stain in the ceiling, tore it out to reveal the cast iron soil stack (runs from the upstairs bathroom turns a corner then runs straight to the basement) and found the leak was around (very bad leak) the lead joint. My husband finally got...

Cast iron vent stack [ 7 Answers ]

I'm installiing a new basement bathroom and when running a vent stack I would like to tap into the existing cast iron with PVC using a saddle on the cast. My question is what method is used to cut a hole in the cast iron, where I wish to place the saddle and connect the PVC.


View more questions Search