    Can a TACO 0010-F3 single phase be a replacement for a B&G series 100 circulator?
    I am not handy. If I buy a TACO 0010-F3 is this a good replacement for a B & G series 100 circulator?
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Nov 21, 2014, 01:05 PM
    A taco 007 or 0010 are both fine replacements for the B&G 100 series circulator as long as the B&G pump isn't an all bronze pump! Wal-mart has the 0010 pump on sale for $187.00 including free shipping!

    Back to you...

    Mark
    Mike45plus's Avatar
    Mike45plus Posts: 230, Reputation: 27
    Full Member
     
    #3

    Nov 23, 2014, 07:03 AM
    Ivyleagr,
    Circulator sizing is based on flow rate and pump head ( friction loss ). The pump flow rate should match the pipe size it is serving, and, the connected load; a circulator should not try to pump more than a pipe can handle.
    Proper circulator sizing will result in measureable electric savings, and, will prevent wear from flow erosion, reduce expansion noise, and will decrease the potential for water hammer. All pump manufacturers will help you properly size a replacement pump via their tech support.
    ECM circulators can further reduce your operating costs, and, increase your heating system overall efficiency; these electronic commutated motors will continuously adjust pump speed to match the required heat load in real time. Certain manufacturers are offering substantial rebates on these new circulators that brings the actual cost lower than most fixed speed replacement circulators..............

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Furnace replacement recommendation for Day & Night model #100U-19A, 100,000 BTU [ 1 Answers ]

Home built in 1975 with DAY & NIGHT furnace model #100U-19A, Input: 100,000 BTU/hr, Bonnet Capacity: 80,000 BTU/hr. Since original construction, 2 rooms added for total square footage at 2,650. Old furnace has rust spots. Expect holes to form soon. Must replace furnace now.

100 amp 3 phase upgrate to 150 amp 600v deffirent [ 2 Answers ]

What deffirent between the 100amp 3 phase and 150 amp 600v

Running two 100 amp main panels from a 200 amp service single lug meter [ 1 Answers ]

I have a 200 amp meter with single load side lugs. Presently my house is tied to these lugs. I'm building a remote garage which will require a 100amp feed. Tieing the house to the garage is not doable due to the location of the driveway. I would like to have the existing 200 amp meter feed...

Can a 150 amp meter panal handel a 100 amp, 40 amp, 30 amp and 30 amp brakers. [ 2 Answers ]

My meter panal is a 150amp panal. I have a 60 amp sub panal coming off it a 30amp to my stove a 30 to dryer and a 40 to the a/c. i want to upgrade the 60 amp sub panal to a 100 amp panal. Will the 150 amp meter panal handel it or do i need to have a 200 amp meter panal installed

Taco 0010-F2 pump [ 1 Answers ]

Hi I have a Taco 0010-F2 pump on my underfloor heat system. Do these pumps lose pressure over time? If so is it normally the replacement cartridge or the electrical windings that cause the problem. Any easy way to test the windings without taking it in? Thanks


View more questions Search