    slashalot Posts: 7, Reputation: 1
    New Member
     
    #1

    Apr 22, 2009, 11:16 AM
    Can the basement venting be tested?
    I know it has been asked and answered many times.

    Is there a way to test it though? Or do I just go with "it should be"

    This is a 1993 build in MI with the 3 pipe slabed rough-in.

    I need to slot the slab and move it 4 feet-ish so as to put a shower unit in. the rough-in was for tub/shower combo and is too close to stool given size of available space of room.

    Will this be a problem to continue the slope of the drain for an extra 4' ?

    Once slab is cut and recemented I can tile the floor and install the stool. Is there and code I should be worried about in the supply side. Very comfertable with sweating copper so not a problem there. Will run 3/4 to shower then 1/2 to sink and stool.

    Thank in advance
    Slash
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Apr 22, 2009, 03:21 PM
    The 4 feet shouldn't be a big issue.. what is more likely to be an issue is that the tub/shower combo. Only requires an 1.5" drain line and showers need 2" pipe. If 2" pipe is present then you are all set. If not and connection into the toilet drain is close by it would be a good idea to increase the size of the drain to 2". You can still use the 1.5" vent pipe (or 2" wet vent) that should be present to vent all this.

    If you don't want to increase the pipe size you could always install a pipe increaser and upgrade to 2" pipe, but the shower drain will probably have a tendency to clog sooner than it would have if you upsized as code requires.

    In terms of water pipes, if you are installing a 3/4" shower valve then run 3/4" pipes to the shower valve, but if you're not installing a 3/4" shower valve, but just a regular 1/2" shower valve, then just branch off at the sink with a 3/4"x1/2"x1/2" tee fitting and run 1/2" to sink and to shower. You should be all set thereafter... ;)

    Let me know if you need more...

    MARK

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Basement Wet Bar Venting [ 9 Answers ]

Ok, so I am in the process of finishing my basement, and intend to add a wet bar. I'm not a very experienced plumber, so I have begun to research how this needs to be done, so it meets code and so I can avoid surprises when the inspector comes to check things out. On my original plans, I...

Venting from basement [ 3 Answers ]

I'm curious about venting fixtures from the basement. All of the traps in my house (ranch style) are in the basement, not beneath the fixtures themselves. They are beneath the fixtures, but in the basement. The vents do go to the attic, but they run off a upside down tee that is cut after the p...

Basement venting [ 1 Answers ]

I have a manufactured home with a full basement. The basement has a bath area built in, but not complete. The ceiling is not yet installed. I can see the main drain pipe which runs horizontially along the interior of the out side wall. Another main drain pipe runs down from this to the floor of...

Basement Bathroom Venting [ 2 Answers ]

I had my rough in inspection yesterday, and everything looked good except my venting for my sinks. I am installing a bathroom lav and a wetbar sink, running into a 2" wet vent that already has a tub/shower on it. Since the distance to the furthest sink is just under 5' from the wet vent I thought...

Basement Venting [ 1 Answers ]

I recently moved into a year old home that has an unfinished basement. There are rough-ins for a toilet, shower and sink already in place. My questions is what venting needs to be added for these rough-ins or are these vented through the existing plumbing already (or how can I tell)?


View more questions Search