    Hoping you can help me. I have the same problem with my water pressure, except when I check the valve, I just get air. Should I put more air in the tank?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Apr 20, 2013, 09:15 AM
    Hi maryancampos and welcome to The Plumbing Page at ANHD.com. You're responding to a 6 year old dead threads so I gave you one of your own. Please check the date before you post. Thanks
    hoping you can help me. I have the same problem with my water pressure,
    No two complaints are the same so what, exactly would that problem be?
    To charge your bladder tank correctly Shut the pump off at the breaker box and open a cold water tap to bleed off the pressure.
    You will see a air valve on top of the tank. The PSI on the bladder tank should be 2 PSI UNDER the cut in point on the control box. In other words if your pump cuts in at 30 PSI the tank should be charged at 28 PSI. Good luck Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bladder tank! [ 6 Answers ]

Just bought a house new pump with new bladder, when they hooked it up the line goes to the pump down to the bladder and they got a T in the middle and its running to the house! Pressure in house sucks! It I move the T down to the bladder tank will that help?

Bladder tank [ 1 Answers ]

How long does it take to drain the bladder tank

Storage Tank or Bladder Tank? [ 8 Answers ]

We just had a new well put in. The well person installed a 220 gallon storage tank (not bladder) when we turn on our sprinkler system our submersible well pump cuts in every 50seconds. We are using approximately 16 gallons per minute. Should the well person have put in a bladder tank instead of a...

Can't charge tank with new bladder [ 6 Answers ]

Hi, I have a flotec 35 gallon pressurized tank with a busted bladder, bought the new bladder and placed it inside, but can't seem to charge it, the air keeps coming out of the bottom hole of the tank, isn't the new bladder suppose to hold the air in? Everything is tight as can be, but no luck...

Replacing a bladder tank [ 2 Answers ]

I have a 18 year old Perma Tank PAD 20. According to all the prior dialog on this site about pressure drops and short cycling, it sounds like I have a ruptured bladder. The tank clunks all the way to the top and water comes out the pressure valve. I'm pretty handy. Is a bladder tank something I...