New Member
|
|
Aug 8, 2009, 04:34 PM
|
|
Bladder Tank Location? Is it needed?
Lm renovating a rental. The rental is fed from a house 60ft away. The house that's feeding the rental is on a well supplying 7.5 gpm. The main house has a bladder tank with the proper electrical apparatus etc. Lots of water! Now. The cold water line entering the rental runs in this order 1st the laundry, 2nd the bathroom, third the kitchen where this small bladder tank sits above the H/W tank on a shelf. The only cold water traveling past this point is the kitchen taps 8ft away. The hot water line travels back the same path the water main does in, stopping at the laundry room.. With all said: Do l need that bladder tank? Is it doing anything? Is it just giving me more pressure 8ft to the sink in the same room? Thank you.
|
|
 |
Home Improvement & Construction Expert
|
|
Aug 8, 2009, 06:35 PM
|
|
Sounds more like an expansion tank for the water heater than a bladder tank for a well.
|
|
 |
New Member
|
|
Aug 8, 2009, 08:37 PM
|
|
Thanks.
Harold: the tank is connected to the cold water pipe, not the hot.
|
|
 |
Eternal Plumber
|
|
Aug 9, 2009, 05:01 AM
|
|
The widget maker nailed it again. You have a expansion tank,(see image) not a bladder tank. This's necessary if your water system has a backflow preventer,(see image) or check valve installed. Regards, Tom
|
|
 |
New Member
|
|
Aug 9, 2009, 09:16 AM
|
|
Hi Speedball 1, nice diagram however, that's not it either. L found the brochure hiding behind the tank. It is a Duro-Air cold water pressure tank with a replaceable bladder, model XA 60. It's 15.9 US gallons, 16" diam, 31" height. OK. What would the benefit be having it inslalled in the said location above? Is it helping? Thank you Tom.
|
|
 |
Home Improvement & Construction Expert
|
|
Aug 9, 2009, 10:01 AM
|
|
It adds a little capacity to your water system and probably mitigates water pressure variations when both residences are using water.
|
|
 |
Eternal Plumber
|
|
Aug 9, 2009, 10:28 AM
|
|
 Originally Posted by Rule
Hi Speedball 1, nice diagram however, that's not it either. l found the brochure hiding behind the tank. It is a Duro-Air cold water pressure tank with a replaceable bladder, model XA 60. it's 15.9 US gallons, 16" diam, 31" height. OK. What would the benefit be having it inslalled in the said location above? Is it helping? Thank you Tom.
It's a bladder tank doing service as a expansion tank (see image). The upside of having a bladder tank in place of a expansion is as Harold explained , "It adds a little capacity to your water system and probably mitigates water pressure variations when both residences are using water."
Anther benefit is that a expansion tank fills up in time with condensate and must be recharged by draining the system. You recharge a bladder tank by simply adding are to the snifter valve. Good luck, Tom
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Storage Tank or Bladder Tank?
[ 8 Answers ]
We just had a new well put in. The well person installed a 220 gallon storage tank (not bladder) when we turn on our sprinkler system our submersible well pump cuts in every 50seconds. We are using approximately 16 gallons per minute. Should the well person have put in a bladder tank instead of a...
How long should a bladder tank last?
[ 7 Answers ]
My bladder tank is a V60 aqua-air, I've had it for 14 years and get my water out of the lake. The pressure in my house has become terrible. I've checked the pressure in the tank and it was 29.5 lbs. could the tank be worn out or could it have dirt in it? HELP Thanks for the help ahead of time.
Bladder tank pressure
[ 2 Answers ]
We have well water. The pressure has streadily decreased. How do I check to see if the bladder tank is working properly.
Can't charge tank with new bladder
[ 6 Answers ]
Hi, I have a flotec 35 gallon pressurized tank with a busted bladder, bought the new bladder and placed it inside, but can't seem to charge it, the air keeps coming out of the bottom hole of the tank, isn't the new bladder suppose to hold the air in? Everything is tight as can be, but no luck...
No pressure in bladder tank
[ 1 Answers ]
I have a bladder tank installed at my home. We had to cut the power to the tank off several days ago due to a replacement of an external pipe. When we turned the power back on, there is a humming sound as soon as any faucet is turned on, or whenever any toilet is flushed. There is a meter on the...
View more questions
Search
|