    I am unable to get anything more than 20# pressure on my well.
    I have plenty of water as I can physically look down my well and see it. I also took fishing line and sinker and let it down... plenty of water. We have a very high water table in Sringfield. My well is only about 20 - 40 ft deep. I have changed out my pressure switch twice in my attempt to fix it... each time it was a Square D 30-50. I have disassembled the pressure switch 1/4' piping it connects to to see if there were any blockages. I switched out the actual water pump last night and still no effect. As soon as I flipped the pressure switch lever the pressure goes immediately to 20# and stops. When I open the valve after the bladder I can hear and feel the pump running. It may drop to 12# but it eventually will get it back to 20#. I installed a new Pentair 1/2hp 2wire 230V pump. The only oddity is when I open the valve in front of the <1yr bladder tank just a trickle of water comes out. I would think the tank would empty quite a bit. I have checked the bladder valve and I have 28# of pressure when the system is turned off. No water leakage from the valve. Very poor pressure throughout the house with only 20# present. Any help sure would be appreciated. Thank you!"
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    Oct 27, 2010, 03:47 PM

    How many pipes go from the pump into your well, one or two?
    cmurphyil7's Avatar
    cmurphyil7 Posts: 3, Reputation: 1
    New Member
     
    #3

    Oct 28, 2010, 01:03 PM
    Just 1
    cmurphyil7's Avatar
    cmurphyil7 Posts: 3, Reputation: 1
    New Member
     
    #4

    Oct 28, 2010, 01:06 PM
    Comment on jlisenbe's post
    I'm sorry I replied in the wrong space... Only 1 pipe from the well to the pump. Spoke to a plumber yesterday and he said it would be expected for the bladder to be empty since I'm not getting the necessary 28# of pressure to fill the bladder.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Unable to Finalize a DVD-R and therefore unable to view in any other device [ 2 Answers ]

I am unable to finalize my mini dvd-r in my sony handy cam. I have tried everything and it is not finalizing. My question is: Can I transfer the data from my handy cam to another DVD? Or is the data unable to be transferred because it can't be finalized? Thanks!

Passed gas pressure test at 15 psi, but pressure slowly drops, is this OK? [ 4 Answers ]

Passed inspection on our gas line for a remodel. Have about five capped gas outlets. Pressure held @ 15 psi for 15 minutes but slowly drops about one psi every half hour or so. Is this normal or do I need to search for a gas leak?

New shallow well pump new huge pressure tank but water pressure is terrible [ 11 Answers ]

When I had a smaller pump (shallow well) and small tank my water pressure was great. When I had to replace everything the person installing the system put a bigger pump and a huge pressure tank. It is the size of a 50 gal water heater. I replaced everything. Ever since then my water pressure is...

What is the correct suction pressure and head pressure for a 3 ton tempstar heat pump [ 1 Answers ]

When the yellow jacket brand gauges are put on a 3 ton Tempstar heat pump what should the correct suction pressure and head pressure be. I suspect it to be overcharged in freon. Because it is freezing the compressor, accumulator tank and all the lines soild ice.

Do you add 30 410a freon pressure like you do r22 and r12 for high side pressure in c [ 1 Answers ]

Do you have to add 30 to the ambeint air temp. like you do for r22 and r12 to R410a freon to get the proper high side pressure reading


View more questions Search