    Alternating slow/fast drainage
    Dear Community,

    I have a sink in my bathroom which can't decide whether it wants to be clogged or not.

    After running the water continuously for about a minute with the drain open, water starts to accumulate in the sink. When the depth of water is about two inches (still running the water at the same rate), the rate of drainage "magically" improves and the sink empties. 30 seconds later (still running the water), it starts to accumulate again.

    Should I be looking in the drainpipes or the vent stack to solve this problem? Drainage does not appear to be a problem for the toilet and bath in the same bathroom.

    Thanks in advance,
    -Bob
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    May 11, 2007, 12:38 PM
    Hi Bob,
    Do you have a regular lavatory or a vessel sink? Regards, Tom
    mailbait's Avatar
    mailbait Posts: 3, Reputation: 1
    New Member
     
    #3

    May 16, 2007, 10:05 AM
    Hi Tom,

    (sorry for the delay... my computer works about as reliably as my drains)

    It's a regular lavatory.

    Thanks,
    -Bob
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    May 16, 2007, 10:16 AM
    Hey Bob,
    It sounds like you have a partial blockage in the lateral drain line in the wall
    Remove the "J" bend from the trap and send a snake up into the wall.
    You will run into a bend about 8 inches in but once past that all you'll have to put out is 6 or 7 feet more. Test with a large pan of boiling water. Good luck, Tom
    mailbait's Avatar
    mailbait Posts: 3, Reputation: 1
    New Member
     
    #5

    May 17, 2007, 05:59 AM
    Thanks Tom!

    I'll give that a try this weekend and will let you know how it turns out.

    -Bob

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Alternating compressors [ 3 Answers ]

Hi there everybody, this is my problem' I have two 3 phase 10 hp compressors connected to one air tank, each compressor is on its own circuit and its own pressure switch at the moment only one compressor comes on because of the pressure switch, I’ve tried adjusting the other one to get it the same...

Forced Air Furnace flame good, fan goes slow then fast then slow, etc [ 1 Answers ]

Hello, I have a forced air propane furnace in a "Park Model" rv trailer. (This is a bit smaller than a mobile home) The furnace is used infrequently as the trailer is located in a sumer resort vacation area, however we do like to go up a couple of times in the winter months. Furnace was...

Slow tub drainage [ 16 Answers ]

We recently remodeled bathroom. Replaced sewer line for tub/shower. Put in new drain/tub/shower etc. I expected the tub to drain with voracity. But it does not. When the washer drains into the washtub in utility room, the water still backs up into the tub. Very disappointed. What causes...

Computer running real slow, speed isn't as fast as before [ 2 Answers ]

My comp is running real slow now, dun noe what has happened Logfile of HijackThis v1.99.1 Scan saved at 12:59:44 PM, on 24/02/2005 Platform: Windows XP SP1 (WinNT 5.01.2600) MSIE: Internet Explorer v6.00 SP1 (6.00.2800.1106) Running processes: C:\WINDOWS\System32\smss.exe...


View more questions Search