    Dec 6, 2008, 09:32 AM
    Adjusting pressure on Pumptrol Pressure Switch
    Model #9013FSG2J21BP
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    Dec 6, 2008, 10:25 AM

    This site will tell you how it's done. Basically, turning the large center nut will adjust both the cut in and cut out pressures. Turn it clockwise to move pressure points up, counterclockwise to move pressures down. Using this nut will maintain about a twenty pound differential between the cut in and cut off points.

    The small nut will adjust only the cut off pressure.

    How to adjust water pump pressure, pump cut-on pressure and pump cut-off pressure - private pump and well system do-it-yourself repairs
    jmhall's Avatar
    jmhall Posts: 1, Reputation: 1
    New Member
     
    #3

    Jan 17, 2012, 07:32 PM
    Sometimes our switch will not kick on, it is a brand new switch. Is there an adjustment for this or why does it happen. We have to go to the well house and trip the switch to get it to kick on.
    paleczny's Avatar
    paleczny Posts: 1, Reputation: 1
    New Member
     
    #4

    May 5, 2012, 01:51 PM
    Is your pump switch working better now. I have an older switch and often there is a delay in the pump starting. NO water coming. I am now going to check my pressures on the swictch and set them at 20 psi to start and 40 psi to stop.
    Please advise what you did to free your sticky switch.

    Thanks, Paul
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #5

    May 5, 2012, 03:40 PM
    Two items:

    1. The little pipe leading to the switch can get clogged and make the switch sluggish.

    2. Older switch can = worn out. They are cheap to purchase and easy to install if you are comfortable with doing that kind of thing.
    snyderman's Avatar
    snyderman Posts: 1, Reputation: 1
    New Member
     
    #6

    Oct 31, 2012, 08:11 PM
    Some times during the day the pump goes off,Then I have to click the breaker to start the pump??
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #7

    Nov 1, 2012, 06:58 AM
    If your pump keeps throwing the breaker then it's calling for more amps then the breaker's set for. This could be a bad capacitor or a short in the motor windings. How many amps is the breaker? I'd have the pump checked out ASAP. Good luck, Tom
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #8

    Nov 1, 2012, 04:55 PM
    Good answer by Speedball. The only other culprit that comes to mind might be defective buried cable. If you have buried cable, you can try unhooking it at the switch, then see if the breaker continues to throw. If it does, then you have found the problem.
    natmur's Avatar
    natmur Posts: 1, Reputation: 1
    New Member
     
    #9

    Jun 10, 2014, 09:46 AM
    Im needing to up mu water pressure and after reading the site that was mentioned on here, I am nervous to touch the nuts in fear of getting shocked. My cellar is very wet and the floor often has puddles, is there anything I can do besides shutting off the whole thing, because then I have to prime the pump and it is a right pain.
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #10

    Jun 10, 2014, 10:49 AM
    Shut the breaker off. That should have no impact on having to prime the pump. When you adjust the switch, bear in mind that quarter-turns don't accomplish much. Take a full turn at a time. It's trial and error. Clockwise to go up, and CCW to go down. There are two nuts. Adjust the large one in the center.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pumptrol Pressure Regulator adjustment [ 12 Answers ]

How do I adjust the pressure regulator on a Pumptrol to increase the amount of pressure?

How to wire a 20-40# pumptrol pressure switch for a deep well? [ 4 Answers ]

Hi all: My daughter asked me to wire power to her deep water well... I will be using #12 2 wire w/ ground through a 20 amp circuit breaker to a 20-40# pumptrol pressure control switch... The pumptrol has four terminals in a line, the two end terminals are marked "L" and the two center terminals are...

How to change sq. D pumptrol pressure switch? [ 5 Answers ]

Hi. I am using well water for my residence. Lately I start having pressure problem. The pressure switch is not activating when the water is flowing and the pressure goes down to 20 psi then drops to zero. After awhile the switch activates and build up the pressure to 100 psi. The switch is set for...

Adjusting psi on Square D Pumptrol switch [ 1 Answers ]

My irrigation system requires the well pump psi to be set above 30 psi on the low end or else it drains the well. Once I cut the power and remove the cover to the Pumptrol switch, I turned down (clockwise) the center spring loaded screw down (the higher one upon which the cover was affixed). That...


View more questions Search