Ask Experts Questions for FREE Help !
Ask
    mohsoko's Avatar
    mohsoko Posts: 1, Reputation: 1
    New Member
     
    #1

    Dec 7, 2007, 01:02 AM
    Who can answer about chiller
    How can I calculate the size for chiller and AHU unit PIPE :) :) ?
    queens's Avatar
    queens Posts: 6, Reputation: 1
    New Member
     
    #2

    Dec 14, 2007, 02:56 AM
    Hi, for your question, you have to refer to some professional book. I can give u some guild so you can get those information easier. Most of the chiller and AHU are using water cooling pakage to condense the gas (cooling tower) WCPU and air cooling pakage ACPU, and its calculate by using water tonage and sizes of fan. The sizes of those pipe line are depends on the tonage of cooling tower. Chiller and AHU are clasify by the cool air's flow rate (BTU- British Thermal Unit). To decide the sizes of chiller, consider these- occupying area(indoor,outdoor); heat transfer (condution/ convection, radiation) from wall, window, roof (heat transfer coefision); environment condition (dry pulp temp, wet pulp temp, humidity); occupying condition (room or hall or what). There is a chart call Phychometry Chart, you can get it from any air conditioning engineering book.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Chiller plant manager [ 1 Answers ]

Hi Could u tell about chiller plant manager provided in chillercontrol itself. If we are controlling chiller and pumps by BMS system I mean start/stop command based on installed temp. sensor or pressure sensor. In this case what is the benefit of inbuilt chiller plant manager.

Chiller diff pressure [ 1 Answers ]

Our chilled water system is rated 4050 GPM 100psi with 40-45 diff pressure, is this differential the process demand? How can we use this to calculate primary chiller pump dynamic head and is this also affecting the secondary chiller pump TDH?:confused:

Chiller pump [ 1 Answers ]

How to calculate chiller pump head

Burying Chiller Piping [ 1 Answers ]

We are having an issue with a certain chiller pipe eroding due to soil conditions we are replacing this pipe and I am curious as to whether anyone might provide me with a solution for protecting the tubing from the underground elements. Here are the specifics; piping = 2" copper, ground type =...

Query regarding Chiller [ 2 Answers ]

Dear Sir, We have LG Steam driven Absorption Chiller of 500 Ton with following specs 1) Chilled water flow 302 m3/hr 2) Chilled water Temp 7 to 12 C In these specs, rated or max flow requirement gainst 500 Ton is mentioned. Please tell me 1) What is the minimum flow...


View more questions Search