    pump head calculation?
    The airconditioning air cooled chiller of 75tr are 2 no"s on second floor terrace level & AHU"s are at first floor level & each floor level height is 15 ft.

    totally there are 14 AHU"s.

    I want to know below specified calcucaltions? FOR CLOSED PIPE SYSTEM

    what is the pump head?
    what is pump motor capacity (if motor is kirloskar)?
    pipe size of suction (from AHU to chiller )?
    pipe size of discharge (from chiller to AHU )?
    what are all pipe frictional loss? fps?
    the sum of all friction pressure drops?. in deatil
    what will be the elbow,valves, friction loss?

    ANOTHER QUESTION?.

    M.S.PIPE C-CLASS,B-CLASS,A-CLASS SPECIFICATIONS?
    BALL VALVE,BUTTERFLY VALVE,EXPANSION VALVES(BELLOWS),BALANCING VALVE,NON RETURN VALVE,3-WAY VALVE TECHANICAL SPECIFICATIONS FOR PROCURING THE MATERIAL?.
    caibuadday's Avatar
    caibuadday Posts: 460, Reputation: 10
    Full Member
     
    #2

    Sep 12, 2007, 05:47 PM
    Quote Originally Posted by rajuas100
    The airconditioning air cooled chiller of 75tr are 2 no"s on second floor terrace level & AHU"s are at first floor level & each floor level height is 15 ft.

    totally there are 14 AHU"s.

    i want to know below specified calcucaltions?.FOR CLOSED PIPE SYSTEM

    what is the pump head?.
    what is pump motor capacity (if motor is kirloskar)?.
    pipe size of suction (from AHU to chiller )?.
    pipe size of discharge (from chiller to AHU )?.
    what are all pipe frictional loss?.fps?.
    the sum of all friction pressure drops?.....in deatil
    what will be the elbow,valves, friction loss?.

    ANOTHER QUESTION?........

    M.S.PIPE C-CLASS,B-CLASS,A-CLASS SPECIFICATIONS?.
    BALL VALVE,BUTTERFLY VALVE,EXPANSION VALVES(BELLOWS),BALANCING VALVE,NON RETURN VALVE,3-WAY VALVE TECHANICAL SPECIFICATIONS FOR PROCURING THE MATERIAL?.......
    #1 the height of the water the colume 1ft h= 0.433 psi (g), 10 ft = 4.33
    #2 the ability of the pump to move water at a given press and volume
    #3 depend on your requirement and the coil's / chiller's spec
    #4 same as 3
    # 5 it is express in INch of water per 100ft of piping( 1 ft = 12 inch=0.433 psi)
    #6 it is express in equipvalent feet of pipe(of the same diameter)
    # 7 actually it called total lost ( friction + head), it is the biggest press lost


    in order to correctly answer Q2-7, you need to know your peak load and the temps you desired
    try to get the specs from the companies you intend to the chiller/ pipes/pump
    caibuadday's Avatar
    caibuadday Posts: 460, Reputation: 10
    Full Member
     
    #3

    Sep 13, 2007, 06:12 PM
    Quote Originally Posted by rajuas100
    The airconditioning air cooled chiller of 75tr are 2 no"s on second floor terrace level & AHU"s are at first floor level & each floor level height is 15 ft.

    totally there are 14 AHU"s.

    i want to know below specified calcucaltions?.FOR CLOSED PIPE SYSTEM

    what is the pump head?.
    what is pump motor capacity (if motor is kirloskar)?.
    pipe size of suction (from AHU to chiller )?.
    pipe size of discharge (from chiller to AHU )?.
    what are all pipe frictional loss?.fps?.
    the sum of all friction pressure drops?.....in deatil
    what will be the elbow,valves, friction loss?.

    ANOTHER QUESTION?........

    M.S.PIPE C-CLASS,B-CLASS,A-CLASS SPECIFICATIONS?.
    BALL VALVE,BUTTERFLY VALVE,EXPANSION VALVES(BELLOWS),BALANCING VALVE,NON RETURN VALVE,3-WAY VALVE TECHANICAL SPECIFICATIONS FOR PROCURING THE MATERIAL?.......
    Opppp!! It is FEET OF WATER per 100ft of PIPING
    rajuas100's Avatar
    rajuas100 Posts: 10, Reputation: 1
    New Member
     
    #4

    Sep 17, 2007, 04:00 AM
    m.s.pipe c-class,b-class,a-class specifications? for hvac chiller pipe sch.40 or 80>?>...
    Ball valve,butterfly valve,expansion valves(bellows),balancing valve,non return valve,3-way valve techanical specifications for procuring the material?.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pump head calculation for closed system? [ 1 Answers ]

Dear Sir/Madam, I want to know the chiller pipe pump head caculation for closed system?

Rain shower head & handheld shower head problem [ 4 Answers ]

I have a shower with 2 pipes for showers heads (one on the wall in front, and one on a side wall). The wall in front has a rain shower head on it. The wall to the side has a hand held shower head attached. The pipe with the hand held shower attached has a push button valve to turn the handheld on...

Pump calculation [ 12 Answers ]

How can I know that the selection water booster pump is suitable for the system?

Sump pump volume calculation [ 3 Answers ]

I'm currently trying to solve a sump pump capacity problem. I never have water in basket except in very bad 5+ inches of rain in short periods 1/2 day or less. Then it comes so fast It is almost impossible to keep up with. I'm planning on installing a new Zoeller pump capable of 93 gpm with 10...


View more questions Search