    Ethernet wiring installation.
    I'm installing a piece of equipment which I want to be able to program remotely. I have run Cat5e cable about 350 ft from equipment to server room. Do I need a switch or repeater for the cable being 350 ft long? If so, how and what kind? Also, I believe the RJ45 connector wiring needs to be T568B but not sure. Does it matter?
    chuckhole's Avatar
    chuckhole Posts: 850, Reputation: 45
    Senior Member
     
    #2

    Sep 11, 2008, 07:26 AM
    Both ends ar typically set up as T568B connections unless you need a crossover cable which would have T568A at one end.

    350ft is pushing the specifications of Cat5e UTP. It likely will work though. You can increase your odds by decreasing the number of connection points to patch panels, wall plates, etc. To each of these type of connections, maintain the twist in the wire as close to the connection as possible. The possibility of crosstalk occurs most at these connections and at sharp bends in the cabling.

    Adding switching gear will not amplify the end-to-end connection. Only a repeater will do this and it is worth considering the use of fiber optic cabling instead of spending money on this type of gear.
    Dave Ermeling's Avatar
    Dave Ermeling Posts: 173, Reputation: 3
    Junior Member
     
    #3

    Sep 11, 2008, 03:28 PM
    Chuckhole, our network uses T568B everywhere else I believe. I guess that's what I'll use. The manufacturer of the PC that we're connecting to said it didn't matter which one we used. I'm going to try it without the repeater 1st I guess. The cable goes point A to Point B. I've eard a few different opinions on the switch/repeater issue now.
    Thanks,
    Dave

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Wiring Installation [ 1 Answers ]

I have a 2 stage heat pump system. I've recently purchase a new thermostat. While doing this install, I noticed that I had ome unsed wires tucked away. Not sure what the go to, as they are purple, black, light brown and blue. To see if they were connected anywhere, I went into the garage and...

Wiring Installation [ 5 Answers ]

I'm replacing a 4 year old non-programmable thermostat (Totaline (Model #P474-0100)) for a Carrier unit with a programmable thermostat (Lux (Model #TX9000TS)). The question I have is the labeling for the wires are different... what wires go where on the new system? I also noticed some unused...

Installation of Transformer wiring [ 1 Answers ]

I have central heating and my Transformer has burned out. I have a new Transfomer and I'm having trouble installing it with the different types of wires. Can you please assist me with installing the correct wires into the Transformer.

Themostat wiring installation [ 1 Answers ]

I just bought a new themostart to replace with the old one I only have heating and the wiring diagram showing I have to connect one to R and one to W(heating relay) The wire I have from the wall one is red and one is white which I don't know which one should I connect to the R and which one...

Subpanel installation and wiring [ 1 Answers ]

I am constructing a wood working shop that is about 40 feet from my cabin in NC. The plan is to feed 240v 30amp from the main panel using 10/3 grounding outdoor wire. A subpanel will be installed in the shop with breakers for lights and outlets. The shop will contain a sander, grinder, drill...


View more questions Search