    Earthing transformer
    Hi guys,
    Can anybody tell me what is an earting transformer.
    What is the fuction and how it is conencted to the electrical system?
    Thanks
    Moshood Akangbe's Avatar
    Moshood Akangbe Posts: 2, Reputation: 1
    New Member
     
    #2

    Jan 24, 2009, 11:31 AM
    Please, what is earthing transformer? And what is the purpose of its installation?
    Moshood Akangbe's Avatar
    Moshood Akangbe Posts: 2, Reputation: 1
    New Member
     
    #3

    Jan 24, 2009, 11:38 AM

    What is earthing transformer?
    vikramvijayk's Avatar
    vikramvijayk Posts: 1, Reputation: 1
    New Member
     
    #4

    Mar 31, 2011, 01:07 PM
    Earthing transformers are used to create a neutral point in a three-phase system, which provides possibility for neutral earthing. The earthing can be through an arc-suppression reactor, a neutral earthing reactor or resistor or directly.

    The design can be a transformer with just one winding, which is zigzag connected. The zero sequence impedance of such a winding is normally quite low, but it can be increased if the purpose is to limit the current through the transformer in case of an earth fault somewhere in the system. Figure shows the connection diagram.

    During undisturbed system operation with balanced (symmetrical) voltages the current through the earthing transformer is small & of the same size as the magnetizing current. Unbalanced voltages will cause some higher currents flowing through the earthing transformer, which it must be capable to carry.

    An alternative connection to the zigzag is star/delta connection where the delta connected winding will compensate the zero sequence magnetic fields so it will be confined to a leakage field between the star and the delta winding and make the zero sequence impedance of the transformer relatively small. However, if it is desired to increase the zero sequence impedance, this can be achieved by opening the delta connection and insert a reactor or resistor




    It is possible to provide the earthing transformer with a secondary winding for continuous auxiliary station supply.

    Earthing transformers are usually oil immersed and may be installed outdoor. In cases where a separate reactor is connected between the transformer neutral and earth, the reactor and the transformer can be incorporated in the same tank.

    When the earthing transformer is going to be used together with an arc-suppression reactor, the rated current (and its duration) of the earthing transformer will be determined by the data for the arc-suppression reactor.

    If the earthing transformer is used for directly earthing or through a current limiting reactor, the neutral current through the transformer will be high but the duration is limited to a few seconds. Earthing transformer must be designed to withstand the thermal and mechanical effects of the rated neutral current. The characteristic of earthing transformer should be selected to match the property of the system.

    Most of the time in service the loading of earthing transformers is very low. It is the randomly occurring short – duration currents that cause any heating of significance. Ageing of the cellulose materials is then not a matter of concern. Regarding acceptable temperatures there are two aspects to consider. The temperature during currents of say 10 seconds duration must not cause softening of the winding conductor material, say 250o C for copper and 200 o C for aluminium.

    For currents with duration in the order of hours or more, temperatures that cause excessive gas development in the oil should be avoided. Temperatures for items in direct contact with the oil should then not exceed 140 o C

    The system earth fault protection relay may not be effective at low currents. To prevent damage to earthing transformer by such current, oil thermometer with alarm/trip contacts is recommended. Alternatively, the value of maximum continuous earth fault current may be declared and sensitive protection provided.

    For earthing transformers that carry continuous load because of a secondary winding that supplies local consumers.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Transformer [ 10 Answers ]

Hi I've constructed a velleman amp, 2x30watt output, model K4003. Now to power this you need a 50Va transformer. I bought one and the pins along the input side are labelled 0 120 0 120 and the output 0 12 0 12

Transformer [ 3 Answers ]

What happens inside a transformer that increases or decreases the voltage?When a transformer steps up voltages,from where it creates thes voltages?

Transformer [ 1 Answers ]

Hi guys I'm having trouble finding a replacement transformer for my heating unit. The model number is AT140B1123. It's a Honeywell product but I can't find it on their website. Thanks Lou

Transformer [ 5 Answers ]

How can you tell if you have blown a transformer? Also, does anyone know where I can find a part number for my transformer without being able to get to the part itself? I have a model number of 58PAV. The circuit board is HK42FZ009. I believe it is Carrier but not 100%

Earthing [ 3 Answers ]

Hi pals I had to replace my smps twice , I don't know what happened when I took it for repair , I was told that there was a short circuit and the board in smps is blown,so when I asked why did it occoured , I was told tat I didn't had earthing to my PC, now what is this earthing and how...


View more questions Search