    #1

    Oct 22, 2010, 07:29 AM
    York Furnace not working, 6 flash error code - HELP!
    Hi, I have a 6 year old york furnace that doesn't seem to be working anymore. The burner turns on for 20 sec each time up to 3 times then goes out. I took out the ignition sensor and cleaned but doesn't seem to work.

    When I look at the error code, it gives me 6 flash lights. Any Help would be appreciated.

    Thank You.
    zanec's Avatar
    zanec Posts: 26, Reputation: 3
    New Member
     
    #2

    Oct 22, 2010, 07:39 AM
    Check the error codes on the back of the panel. That should help you. Might be a pressure switch, clogged vent tube, induced draft fan not working.
    Tabrez786's Avatar
    Tabrez786 Posts: 2, Reputation: 1
    New Member
     
    #3

    Oct 22, 2010, 07:50 AM
    Comment on zanec's post
    All the fans tend to work, it goes through a proper process, the pilot comes on, the flame comes and goes out after about 30 sec.The panel does say it's related to a pressure switch. Are there any diagnostics I can do before calling in and save $$$?
    zanec's Avatar
    zanec Posts: 26, Reputation: 3
    New Member
     
    #4

    Oct 22, 2010, 02:35 PM

    Ohm out the pressure switch to see if it's functioning properly while the fan is on. Also take the hose off the pressure switch to see if there is a blockage by blowing in it. Sometimes dust and debri can clog the hose.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

York Diamond 80 - 7 flash error code [ 1 Answers ]

I have a York Diamond 80. Will not light. Have done some research on here, cleaned the flame sensor, still no luck. Failed to ignite and locks out after three tries. What is the next step. What do I check? If anyone can help, great. Thanks

York furnace flash error code 6 times (blowing cold air) [ 3 Answers ]

Hello, I have a York (forced air) gas furnace that's 9 years old. Every winter it seems like I have to replace the pressure switch ( round switch with 2 connections & air hose). I hear the blower come on, burners ignite and then within a few seconds they go off with the red light flashing 6 times....

Error code for "open pressure switch" on York natural gas furnace [ 6 Answers ]

I get three red flashes from the furnace after an attempt sequence when the t-stat calls for heat. The motor starts, and seems to try to light but after about thirty seconds, it quits and gives the error code. I have removed both gray tubes from the pressure switch and made sure they are...

White rodgers 50a50-288 1 flash error code [ 7 Answers ]

My furnace is intermittently not starting. It is an Amana with a White Rodgers 50A50-288 module in it. The error code I'm getting is "one flash." It says this is "Lockout - check furnace." Yep, furnace is still there... what am I SPECIFICALLY to check? Any suggestions?

Trane xe80 4 flash error code [ 1 Answers ]

My 8 year old Trane XE80 heat comes on then when it cycles off the fan keeps running and I get 4 flash error code. Help please. Thanks