    2N2L's Avatar
    2N2L Posts: 1, Reputation: 1
    New Member
     
    #1

    Mar 23, 2008, 05:33 AM
    Wiring old taco zone valves 555-102 to furnace
    Help! I have a two zone system of water base boards hooked up to an oil furnace (or is it a boiler?). I had it serviced a month ago and I just realized that the wiring on the two zones, which are controlled by taco 555-102 zone valves, was reversed so that the wrong thermostat controlled the wrong zone. I tried to fix it and now have completely messed up everything. :(

    Here is the wiring that I have:

    I have two sets of wires coming from my thermostats, they are simple red and white wires.

    I have one set of wires going to the furnace they are white, green, and red. The white and green ones on the furnace wire are stripped at the ends and a bit up so that they can connect to both of the zone valves at the same time.

    The zone valves each have three screws: from front to back s1 s2 s3.

    Most of the advice I have found online has referred to additional wires like yellow, but these are all I have. Any help would be appreciated!

    Thanks,
    Kenn
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Mar 23, 2008, 10:02 PM
    Terminals 2 & 3 go to the circulator relay. Terminal 1 goes to one of the thermostat wires. The other thermostat wire goes to one side of the 24 volt transformer that powers the zone valve and the other transformer terminal goes to Terminal 2 (also)

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

2 zone oil heat, 2nd zone runs 1st zone [ 1 Answers ]

Hi, We have a 2 zone oil burner. The 1st zone (upstairs) runs separately and works no problem. The 2nd zone(basment), when we try to run 2nd zone separately , it seems to run zone 1(upstairs) and the baseboard heating upstairs gets hot and heats zone 1 even thought we have the t-stat set low...

Wire zone valves [ 3 Answers ]

I have a oil fired boiler with taco 562 zone valves.My wires are from transformer red&green.Wire from thermostat are red& green.On my zone valves the wires are red,green&yellow.Aperson who said he could fix zone valves had taken all wires off the zone valves.The zone valves have numbers 1,2,3,which...

Thermostat 2 zone wiring [ 2 Answers ]

During winter, heat worked great for both zones, one up and one down. When calling for AC now, only down zones works (compressor and fan kick on and AC flows). While the down zones works, it does pump some AC to upper floors, but not a strong air flow, so it does cool, just very slow... The up...

Zone valves [ 2 Answers ]

Looking for a wiring diagram for a new dunkirk boiler . Just the diagram for the 3 zone valves. Company says that the boiler transformer is enough to run three zones ( 24v) . Or do I need to add transformer. Just can't figure out the wiring from one zone valve to another. Contacts on each zone are...


View more questions Search