Ask Experts Questions for FREE Help !
Ask
    N12457S's Avatar
    N12457S Posts: 4, Reputation: 1
    New Member
     
    #1

    Dec 26, 2009, 03:36 PM
    Wiring honeywell th3210d thermostat to goodman mbr1200aa-1 modular blower
    Need a wiring diagram to connect a honeywell th3210d thermostat to goodman mbr1200aa-1 modular blower with 20kw heater coil
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Dec 26, 2009, 04:24 PM
    There should be a complete wiring diagram on the goodman unit. Usually located on the back of the access door.
    N12457S's Avatar
    N12457S Posts: 4, Reputation: 1
    New Member
     
    #3

    Dec 27, 2009, 08:08 AM
    Correct! But this isn't a conventional thermostat. Need to know where white and blue thermostat wires terminate??
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #4

    Dec 27, 2009, 08:12 AM
    Unless you have a heat pump outside you will not need the blue. The White W terminal wire is listed.
    N12457S's Avatar
    N12457S Posts: 4, Reputation: 1
    New Member
     
    #5

    Dec 27, 2009, 08:58 AM
    Where does the blue & white thermostat wires go honeywell TH3210D from modular blowe
    Where does the blue & white thermostat wires terminate on a honeywell TH3210D from agoodman MBR1200AA-1 modular blower with a 20KW heater element ? This isn't a conventional thermostat. Don't want to smoke the control board!!
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #6

    Dec 27, 2009, 10:49 AM
    Unless you have a heat pump outside you will not need the blue. The White W terminal wire is listed.
    N12457S's Avatar
    N12457S Posts: 4, Reputation: 1
    New Member
     
    #7

    Dec 27, 2009, 01:32 PM

    There is no "W" terminal on the thermostat. (E Aux Y G O L R B C )
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #8

    Dec 27, 2009, 02:03 PM
    See page 4 of the below manual for your thermostat TH3210D Honeywell. There is a connection in the manual. Read the directions for 2 heat 1 cool applications since the blower is setup for a heat pump but you only need the electric heat part. AUX or E will bring the heat on and you can connect this to the W on the goodman unit. Make sure you also go through the setup on the thermostat instructions.

    http://customer.honeywell.com/techli...69-1929EFS.pdf

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Wiring honeywell thermostat [ 2 Answers ]

Dear sir, I purchased a honeywell digital thermostat, non programmable, and replacing the honeywell mechanical. The prooblem is i used terminals g y o w2on the old the new has e aux ygolrbc,i can hook up the gyo but,where does the brown wire go.the new honeywell is for heat pump also th321od ...

Changing Honeywell thermostat to Goodman [ 1 Answers ]

I am trying to wire a Honeywell 7500 series thermostat to a Goodman gph1560m41a. The schematics on the manuals do not match. I get heat when I turn on the cold and no cold or anything when I turn on the heat. This is a 24-volt system (on low voltage), 2-stage hot/cold with optional 3rd stage...

Changing a thermostat from Goodman HPT 18-60 to Honeywell RTH6300 [ 1 Answers ]

I am trying to change a thermostat from Goodman HPT 18-60 to Honeywell RTH6300B, but having a trouble to understand the wiring. The old thermostat has connected with six wires: yellow, green, white, blue, red, and orange. Y = yellow wire G = green wire W2 = white wire R = red wire O =...

Blower motor wiring on a Goodman GMP [ 2 Answers ]

I have a Goodman GMP forced air furnace running on natural gas. It is about 5 - 6 years old. It recently went out. The draft inducer would come on and the igniter would glow but then it would shut down without opening the gas valve. I checked and found that the board was never sending a...

Goodman thermostat going to honeywell [ 2 Answers ]

OK here's what I got I have a manual goodman thermostat on a heat pump with auxiliary heat. On the goodman thermostat this is how it was waired, C=blue wire, E= garyish wire, W2= white, G=green, R=red, O= orange. now this is how I hooked up the honeywell, this is vision pro 8000...