    Trane xe 1000 blower motor getting loud and vibrating 2 days later stopped working
    Trane XE 1000 blower motor making noise for past 2 days. Getting louder and vibrating. Stopped working only hums and freon line frost. Bad blower?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jun 16, 2012, 11:03 PM
    Quote Originally Posted by bruce97382 View Post
    Trane XE 1000 blower motor making noise for past 2 days. Getting louder and vibrating. Stopped working only hums and freon line frost. Bad blower?
    Very well could be a bad blower motor. If you replace the motor make sure you also replace the motor run capacitor that matches the motor you are using as a replacement. NOTE: You also said vibration so check the blower wheel for out of balance conditions. If blower wheel is also out of balance just replace the wheel with like same since they are very hard to balance unless you have the proper tools.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Fireplace insert blower auto shutoff not working and damper rod vibrating [ 6 Answers ]

I bought a Hampton Fireplace insert about 6 years ago and had it installed in my fireplace that until then, had glass doors. The insert has worked wonderfully in my house except for two things: 1) the damper rod vibrates and it constantly needs to be adjusted in order to quiet it down. It's very...

Trane xv90 blower motor doesn't. Motor is free, unit is 7 years, not t-stat. Thanks [ 2 Answers ]

I believe I have troubleshot this down to either the blower motor or their Integrated Controller board. 120VAC to motor OK but too many other wires from board to motor for motor control to test (variable speed) without advice or a manual. Motor is rated for 100% duty cycle and has only been run...

Fan Motor or Blower Motor? Trane XB80 [ 0 Answers ]

Outside fan motor clicks and hums - are the fan motor (outside) and blower motor (to circulate the air) tied together? i.e. if one is out, neither will work? If so - how do you diagnose which motor is out? This is on a Trane XB80 Furnace & Air Conditioner

Blower motor to loud [ 0 Answers ]

Lound blower motor & should the fan cage have play in the shaft.I"m able to move shaft in & out about a 3/4 inch.. is that making the loud vibration & huming noise

TRANE XL80 blower stopped turning [ 1 Answers ]

Hi I have a TRANE XL80 Furnace. Couple of days ago the furnace “Blower” started to make humming and grinding noise and it wouldn’t turn. I then would give it a push start by turning it by hand, and it would turn for couple of hours and it would do the same thing. An hour ago, it stopped...