    TH8320 thermostat
    Trying to replace a 30+ year old mechanical t'stat with a Honeywell TH8320. My thermostat is so old that even though I have found pictures of it's sub-base online, the terminal markings are some what different. By that, I mean instaed of having G,RC,Y,RH,and W, mine has G-F,Y-C,4-M,W/H and RV. There is a blue jumper between the RV and 4-M terminals. Can anyone provide a translation of these old markings to the new standard variety. I have an old Carrier A/C with Bryant air handler and electric heat; nothing fancy at all. Can't locate the old scematic for the handler's wire connection.
    esquire1's Avatar
    esquire1 Posts: 2,483, Reputation: 209
    Ultra Member
     
    #2

    Jan 12, 2008, 09:50 AM
    Go to the Bryant air handler, open it up and see how the thermostat wire are there. We can then tell you how to wire at the thermostat
    Frdbrkl's Avatar
    Frdbrkl Posts: 94, Reputation: 7
    Junior Member
     
    #3

    Jan 12, 2008, 05:33 PM
    Quote Originally Posted by munny9068
    Trying to replace a 30+ year old mechanical t'stat with a Honeywell TH8320. My thermostat is so old that even though I have found pictures of it's sub-base online, the terminal markings are some what different. By that, I mean instaed of having G,RC,Y,RH,and W, mine has G-F,Y-C,4-M,W/H and RV. There is a blue jumper between the RV and 4-M terminals. Can anyone provide a translation of these old markings to the new standard variety. I have an old Carrier A/C with Bryant air handler and electric heat; nothing fancy at all. Can't locate the old scematic for the handler's wire connection.
    It looks to me like:

    G-F (Green, Fan)
    Y-C (Yellow, Cooling)
    W/H (White, Heat)
    RV (Red Voltage)
    4M (?? Possibly for motor on stat)

    If I were a betting man, I would wire it thusly:

    Red-R/C jumpered to RH
    Green-G
    White-H
    Yellow-Y
    And if it's digital readout you'll need a common from the furnace to the stat unless it's powered solely by batteries. Use any unused wire on the existing stat wire, and hook it up to C in the furnace, C to the stat.

    This would follow standard wiring conventions, but it's still just an educated guess.

    Good Luck, and I hope this helped.
    munny9068's Avatar
    munny9068 Posts: 41, Reputation: 1
    Junior Member
     
    #4

    Jan 17, 2008, 08:35 AM
    Thanks. The wire from the thermostat comes through the closet wall and attached to a terminal board on the side of the air handler. There are 5 screws there labeled, Y,G,W,4/R and X/F. Only 4 wires of the house wire are visible with the yellow connected to the Y,green to the G, white to the W and red to the 4/R. I do not see any blue wire on this end of the thermostat wire. It appears that the 1976 installers just cut off wires they did not need or use. There is also a short segment of thermostat wire running from this same terminal board to the bottom of the compressor unit. Two wires here; a red wire connected to the X/F terminal on the air handler and a white wire connected to the Y terminal along with the yellow wire from the thermostat. I have found internet pictures of this same old thermostat but the terminals in mine are labeled differented. For instance, mine is G-F instead of G, Y-C instead of RC, 4-M instead of Rh, RV instead of Y, and W/H instead of W. Any help in determing what terminal could/is be used as the 24V common will be appreciated. I certainly don't want to have to run this new TH8320 solely on battery power.

    Even though the blue wire in the old thermostat is cut off and not used, I think I can pull enough to strip the end and attach to a 'C' terminal.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Honeywell TH8320 to Trane XL80 wiring [ 1 Answers ]

Hi, I have Honeywell TH8320 thermostat which I'm trying to connect to Trane XL80. My problem is that it's 2H/1C system with no heat pump but all TH8320 wiring diagrams only show either 2H/2C or 1H/1C. So I got a bit confused. I'd appreciate any help. Thanks!

Urgent: How to wire VisionPro TH8320? [ 2 Answers ]

I recently bought a new thermostat from Honeywell, model VisionPro TH8320. I'm replacing the old thermostat MapleChase 9620 (now Robertshaw 9620). The old one was working correctly. It has 7 wires. I believe I figured how to wire 5 of them, but not sure about the remaining two. I tried different...

Thermostat wiring MapleChase to Honeywell TH8320 [ 4 Answers ]

I have an old thermostat from MapleChase. It has 7 wires and is currently wired as follows: C (black) L (none) R (Red) Y2 (none) Y1 (yellow) E (black) G (green)

BAYSTAT240 to Honeywell TH8320 Conversion [ 1 Answers ]

I am trying to switch my BAYSTAT240 thermostat to a Honeywell vision pro 8000 (TH8320U1008). My old settings were: O: Orange G: Green Y: Yellow X2: Connected to white along with W B: Blue W: (jumpered to U): White


View more questions Search