Ask Experts Questions for FREE Help !
Ask
    ducky0731's Avatar
    ducky0731 Posts: 1, Reputation: 1
    New Member
     
    #1

    May 19, 2009, 03:52 PM
    Tempstar furnace inducer fan motor
    The inducer fan is noisy on our 13 year old Tempstar 80 furnace. It also seems to run after the ignitor fires and continues to run will the furnace is running. Is this normal?
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #2

    May 19, 2009, 06:04 PM
    The inducer must run for the duration of the heating cycle. If noisy, check the flue outlet for debris. If clean, the motor is likely failing. Try lubrication if ports are provided.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bryant Furnace Inducer Motor Fan Squealing [ 3 Answers ]

I have a byrant furnace model 395b - the inducer motor fan squeals and I was wondering if it should be repalced or can I oil it and how? The furnace company wants $100 to look at it and I was wondering if I could do it myself!

Bryant furnace inducer motor blower keeps failing [ 34 Answers ]

I have a Bryant Plus 90 high efficiency furnace, Model 398A, about 14 years old. I am now on my third inducer motor assembly. The plastic blowers on the first two disintergrated. Does anyone have any idea as to why and what can be done to prevent another failure? Besides the inconvenience of no...

Furnace inducer motor [ 5 Answers ]

What are the implications of a furnace inducer motor drawing high Amps?

Inducer Motor Needs Replacing in Furnace [ 7 Answers ]

What can be another solution to problem. Problem, inducer makes hummimg noise. Is $400 cost to replace and another $400 for labor?

Goodman Inducer Motor [ 18 Answers ]

I have a Goodman Gas Furnace installed in 1997 and have been experiencing the following problems: The usual run for the furnace has been inducer motor on, ignition (with flames), and then the blower motor comes on. I have been having the inducer motor come on, run for about three minutes,...