    Tempstar funace says pressure switch is open when it should be closed
    We have a Tempstar furnace. The indicator is reading that the pressure switch is stuck open when it should be closed. The fan still kicks on but it won't light..
    Grady White's Avatar
    Grady White Posts: 1,417, Reputation: 59
    Ultra Member
     
    #2

    Mar 3, 2014, 08:33 AM
    The reason the fan comes on is it is on a timer which turns the fan on "X" seconds after the thermostat calls for heat. I doesn't know or care if the flame lit or not.

    There should be a small hose going from the exhaust blower to the pressure switch. Take it off the blower & suck very gently. If you hear the switch click, the problem is not with the switch. If the switch clicks, use a paper clip to clean out the nipple to which the hose connected at the blower & try the furnace again.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pressure switch reading open when it should be closed on a concord furanace [ 1 Answers ]

I have a concord hvac that has a smart vavle. I change the vavle now its reading that the pressure switch is open when it should be closed. The unit would light at first then go out after about 20 to 30 sec. now it won't do any thing right be the vavle should open or tell the ingtor to light it...

Ameristar Funace pressure switch error [ 0 Answers ]

The pressure switch error just came on on my Ameristar Furnace this morning. I'm unemployed and have to fix it on my own if possible. What are something I can do to remedy this?

Pressure switch stuck open on a tempstar furnace? [ 0 Answers ]

I have a Tempstar furnace that's reading a/an open pressure switch code. How do I correct this issue?

Goodman gas funace pressure switch problem [ 9 Answers ]

I have a Goodman 93% efficient furnace that short cycles the gas burners. It cycles the vent on, starts the igniter, fires the burners and kicks on the blower but the burners only stay on for a short time ( less than 30 seconds). The led on the circuit board gives me 3 flashes indicating " pressure...


View more questions Search