Ask Experts Questions for FREE Help !
Ask
    primitivo's Avatar
    primitivo Posts: 2, Reputation: 1
    New Member
     
    #1

    Mar 6, 2009, 07:56 AM
    Tempstar air handler wiring instruction needed
    I need Help with wiring up a tempstar air handler the thermostat and condensing unit wiring.
    Mikie D's Avatar
    Mikie D Posts: 45, Reputation: 1
    Junior Member
     
    #2

    Mar 12, 2009, 07:02 AM

    Is the a/h being used for heat and a/c ? Do you have a boiler feeding hwh coil in the a/h ?need more information. But the most common wiring is tstat red -R white - W green -G yellow -Y C-common from a/h to one side of condenser contactor and Y to other side of contacter on condenser and if there is a heat pump let me know. Mikie D
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #3

    Mar 12, 2009, 08:15 AM
    Look on the inside of the blower door for the wiring diagram.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Need wiring instruction for Honeywell [ 3 Answers ]

Hello!! I have been told this should be a simple replacement. However I have a trane heat pump and it was running off an old mercury thermostat which I was told to replace. We had some one (stupid) (not a professional) replace it and they installed a one stage thermostat for either electric or gas...

Tempstar Air Handler Dip Switch Settings [ 5 Answers ]

We have a 3.5 ton Trane heat pump with a 4 ton Tempstar variable speed air handler (both units new in 2004). In January we were told that "all the dip switches were OFF"; so they had to have been that way since the unit was installed. The air flow has always been too strong so, at our request,...

Thermostat air conditioner wiring for tempstar gas furnace [ 2 Answers ]

I disconnected my thermostat from the gas tempstar furnace and also disconnected two wires I traced to the central air conditioner. I do not know where to connect the air conditioner black and white wires to on the W,Y,R,G,C. I do not have a manual. Can someone help me?

Transformer wiring of tempstar furnace [ 2 Answers ]

Hi Labman, I had a bad relay (LY2 24 VAC), so I marked the wires on piece of paper to take it off and install the new one. The problem that I lost the paper somehow and I don't have a clue how to install the new one. I know that the I/p is 120 VAC and the o/P 24 VAC. How ever I have 6-wires...


View more questions Search