    Switching freons in same unit
    I have a 10 year old Goodman that has R22. I was told by my service man that R22 will be gone soon and he said that he could change out the airhandler and put 410 in. Through surfing thte internet I have found that R22 is plentiful. My question is can my existing unit be changed to 410 and if so does the 410 cool better, same, or worse
    Then the R22?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jun 11, 2010, 11:58 AM
    Quote Originally Posted by doglegright View Post
    I have a 10 year old Goodman that has R22. I was told by my service man that R22 will be gone soon and he said that he could change out the airhandler and put 410 in. Through surfing thte internet I have found that R22 is plentiful. My question is can my existing unit be changed to 410 and if so does the 410 cool better, same, or worse
    then the R22?
    My question is can my existing unit be changed to 410 and if so does the 410 cool better, same, or worse
    then the R22
    ?

    R-22 and R-410A work under different pressures and the oil is also different. I would not consider doing this and I would call in question any one who says they are in the HVAC trade that tells you different. The service person that told you this is ignorant of these facts.

    There is plenty of R-22 around and R-22 will be around for many years to come. When it comes time to replace your system then the R-410A will come into the picture since no new R-22 units are being built.

    R-22 and R-410A have different chemical propertys. I will keep my R-22 equipment as long as possible because of this fact and a few others.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

What is the purpose of switching relay in ac unit [ 0 Answers ]

I have a old Chrysler airtemp furnace a/c unit model 4213-04 with a digital thermostat. When I turned on the a/c I got nothing. I'm getting 1.2 volts on secondary at transformer and less at limit switch. Is the black box (Honeywell r8226a 1057 1) a switching relay and could this be why the a/c does...

Live in a mobile home with intertherm heat and air unit the unit outside unit has bee [ 1 Answers ]

Live in mobile home with an intertherm unit outside unit is no longer running didn't know if it even needs to be running with the heat

Pleasy let me know how the capacity of a Air Handling unit or a Packaged unit is dete [ 1 Answers ]

Please let me know what factors should be measured to assertain the capacity of a AHU or a Packaged unit. What does it mean by on coil temperature and off coil temperature ?

Rheem-heat-pump-outside-unit-humming but blower unit working [ 3 Answers ]

I have a heat pump and ac unit outside. The inside blower fan still working but the outside unit humming. Are there any quick fixes here

Changed from separate cooling & heating unit to combined unit [ 1 Answers ]

I have a mobile home & when it was set up in 96 we had separate cooling & heating units run off one thermostat. We had a 3 ton ac unit & an electric furnace inside for heat. This past summer we bought a 4.5 ton ac & heating combined unit. We hooked up to wiring that old ac unit was hooked up to...


View more questions Search