Ask Experts Questions for FREE Help !
Ask
    Bambizzle's Avatar
    Bambizzle Posts: 1, Reputation: 1
    New Member
     
    #1

    Feb 6, 2009, 01:18 AM
    Small house won't stay heated
    I've got a few related questions that have been driving me mad. (my wallet too)

    A few notes- The house is mostly gas. No programmable thermostat or double pane glass.

    My heat at night is set below 68 (usually around 65) and it seems to run all the time with very short breaks. I put my hand to the vent when it turned on and it was NOT blowing "hot" air. Not cold but coolish/warm?
    We change our filters about every 45 days. We have heavy drapes, insulated our leaky outlets, added ceiling vent deflectors, close off rooms and run ceiling fans clockwise on low... we seem to be doing everything possible other than the high ticket items but the heat at 65 comes on every 5-10 minutes and blows coolish air.
    The odd thing is... If we crank it to say 71 or 73.. the rooms get warm indeed. Thought no matter what the setting..it should always blow the same temp of air???

    Any help is appreciated!
    Sorry it's so long. :)
    21boat's Avatar
    21boat Posts: 2,441, Reputation: 212
    Ultra Member
     
    #2

    Feb 6, 2009, 02:44 AM

    My thoughts hear is, since the house is so poorly insulated and the thermostat is set at 65/68, that when the forced air blows, it takes longer to heat up the house because the ducts were colder on the initial start up. The forced air takes longer to heat a colder duct than a pre warmed duct. That's why it seems to run better at 71/73. The duct starts warmer and seems to run shorter to feel that heat change quicker.

    To get a better picture of that think of the car and how long the initial length to heat it up. Warm the car and drive it for some time. Park let the air in the car really cool down and restart it. It heat quicker because the dash etc is warmer on the re heat even though it dropped in air temp. The car heater didn't have to heat the heat ducts because the had a life of there own and became a warm rock overnight

    Heating colder furniture and floors takes a lot longer than if they were warmer on the start.
    The base temp of 65/68 just warms up the house air and the solids materials are dense and the stat kicks off before the cold environment the duct started in

    The bottom line hear is insulate the ducts better. Check ducts for air leaks in the basement that can loose the heat before it get to you.

    A low ticket Item that can be done is steps is insulate the attic or what ever is above the ceiling with Unfaced Insulation. While you are up there check to see if the insul is faced the wrong way with the vapor barrier facing you as you look from above and it should be on the warm side against ceiling below you. Don't add more insul directly over a vapor barrier

    How to Inspect Building Interiors and Building Insulation/Ventilation

    How to Inspect Building Interiors and Building Insulation/Ventilation

    Signed 21 Boat

    If I Helped To Answer Your Question Please Rate My Answer
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #3

    Feb 6, 2009, 02:46 AM
    My heat at night is set below 68 (usually around 65) and it seems to run all the time with very short breaks. I put my hand to the vent when it turned on and it was NOT blowing "hot" air. Not cold but coolish/warm?

    If you want to test the temperature of your air discharge and be accurate you need to take the return air temp and the supply air temp and subtract the return from supply. That will give you a ruff heat rise across the furnace heat exchanger.

    close off rooms

    Your system was designed to operate properly with all registers and return air paths open. You can close off registers but that can throw off the proper operation of the furnace.

    but the heat at 65 comes on every 5-10 minutes and blows coolish air.

    The main question is how long does the furnace operate. This is called duty cycle. On gas this figure is ruffly 6 times per hour or 6 cycles per hour.

    The odd thing is...If we crank it to say 71 or 73..the rooms get warm indeed. Thought no matter what the setting..it should always blow the same temp of air???

    The longer the furnace run time the warmer the room will get and the warmer the discharge temp will be. Remember the relationship I explained before?

    ((If you want to test the temperature of your air discharge and be accurate you need to take the return air temp and the supply air temp and subtract the return from supply. That will give you a ruff heat rise across the furnace heat exchanger.))

    The differential between of the supply and return will stay the same on a properly running furnace. The differential between the supply and return (the spread of the temperature) is the critical factor.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Foreclosure in Michigan how long can I stay in th house [ 2 Answers ]

I live in Michigan, can you tell me how long I can say in my house? The last payment I made was September 1 2007, and what can I do to prolong having to leve the house. I need to save as much money as possible.

Heater shuts down before house is heated [ 2 Answers ]

Carrier heater on heat and air unit turns off after 4 minutes before the house is warmed. And then off and on in short bursts thereafter The house gets warm eventually the heater is always doing this. This was a new house with a new unit two years ago and has been like this since moving in and...

Inexpensive way to keep empty house heated [ 1 Answers ]

I have a small vacation home whose only heat source is a gas stove. It does a great job at heating the entire house when I'm there. But when I'm not there (for weeks at a time), what's the best way to keep the house minimally heated to avoid mold and mildew?

Furnace will not stay on to heat house [ 3 Answers ]

For some time now I have been having trouble with my furnace. When I turn up the thermostat to cut in the furnace, it comes on for about 5 minutes and then stops. The only way to get it to come on again is to turn the power off to the furnace and then on again. After doing this it cycles again...

Small inch worm like things crawling all over outside my house [ 0 Answers ]

Starting last night I discovered small brown 1/2 inch long "worms" or inch worms crawling all over my driveway, sidewalk, front doors and garage doors. Now they are still there on the 2nd day. Checked with the neighbors and 2 other homes have them also. Have no idea what they are but it is...


View more questions Search