    Short cycle burner
    Have a Goodman GMT115-5B Natural Gas. Burners fire and blower comes on. If it has run for a longer period (not too long in my opinion), burner cycles on and off while blower is still running. Burner will ignite burn for 45-60 seconds and shut off then cycle back on again. Cycle will continue to repeat until thermostat reaches temp. Any thoughts?
    Joshdta's Avatar
    Joshdta Posts: 2,549, Reputation: 45
    Ultra Member
     
    #2

    Nov 9, 2009, 04:02 PM

    Air filter dirty, gas pressure to high, return or supply registars closed. Or a week limit.
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #3

    Nov 9, 2009, 05:08 PM
    If the circuit board has a diagnostic LED, it will provide clues.
    novicehvac's Avatar
    novicehvac Posts: 3, Reputation: 1
    New Member
     
    #4

    Nov 11, 2009, 03:54 PM
    Quote Originally Posted by novicehvac View Post
    Have a Goodman GMT115-5B Natural Gas. Burners fire and blower comes on. If it has run for a longer period of time (not too long in my opinion), burner cycles on and off while blower is still running. Burner will ignite burn for 45-60 seconds and shut off then cycle back on again. Cycle will continue to repeat untill thermostat reaches temp. Any thoughts?
    Now, the burners come on and fire for 12-14 second then shut off, and cycle repeats. I have checked and indicator light is not flashing, no error codes are showing.

    Thoughts?
    Joshdta's Avatar
    Joshdta Posts: 2,549, Reputation: 45
    Ultra Member
     
    #5

    Nov 11, 2009, 03:57 PM

    Could be the limit switch or the flame sencer
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #6

    Nov 11, 2009, 03:59 PM
    Try bypassing the thermostat to see if cycle is sustained. Connect "R" and "W" circuits together, either at thermostat location or at furnace.
    novicehvac's Avatar
    novicehvac Posts: 3, Reputation: 1
    New Member
     
    #7

    Nov 11, 2009, 10:18 PM
    Quote Originally Posted by Joshdta View Post
    could be the limit switch or the flame sencer
    Cleaned the flame sensor, changed the filter, by-passed the stat. No change in propblem. Which limit switch and can I check it myself?
    Joshdta's Avatar
    Joshdta Posts: 2,549, Reputation: 45
    Ultra Member
     
    #8

    Nov 12, 2009, 03:36 PM

    http://store.hamiltonhomeproducts.co...-29041-005.jpg

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Short Cycle [ 1 Answers ]

I have a coleman Evcon forced air nat gas furnace. It will cycle or ignite the main burner for 10 seconds and then cycle off. I thought the thermostat was bad so I replaced it the problem still exists. HELP it is getting very frigid and I need the heat.

Shutting down after each short cycle! [ 1 Answers ]

I live in an older mobile home with and heat with a Colleman model 7956-856 gas furnace. If the pilot lite is lit and left on pilot only, it will remain lit without problem. When the furnace is turned on, the cycle is completely random and when the burner kicks off, the pilot turns off with it. Any...

Oil burner short cycles [ 1 Answers ]

I have a Carlin hot air oil fired system. The burner appears to short cycle when the stat calls for heat. Once the stat calls for heat the burner fires up and runs for a few minutes after the fan comes on. Then the burners shuts down for a few minutes while the fan still runs and fires up again....

Furnace burner slowly dies out during heat cycle [ 1 Answers ]

Heil NG furnace, forced draft, intermittent ignition, about 10yrs old. It fires fine after a call for heat from t'stat, with all areas of the burner lit. However, after about 10 minutes the burner looks as if only about 25% is lit. I'm not sure if it ever completely dies out. I don't think so...

Heil furnace short cycling of burner [ 1 Answers ]

My 1983 heil model NUGK075DG01, natural gas, forced air furnace is running but only heats the house to 67 degrees no matter how high I set the temp, the fan continuously runs (in auto on thermostat) and the burner will cycle for 3-4 min. then shut-off for 10 min.. I have powered down and back-on,...


View more questions Search