    Return not connected to the furnace
    I have a not air system. My basement (in my one story house plus bedroom loft) is unfinished but I work in it year round. I recently had a HVAC installer redo the duct work because it was not done properly. One return was entirely blocked off. So, when they finished installing the new duct work, both returns were opened but not connected to the furnace. The returns empty out into the basement area. They installed two heat duct grills in the basement and they installed a return grille in the bottom of the furnace. I am disturbed because the first floor returns have not been connected by any duct work back to the furnace. Today the HVAC workers came and decided to block off one of the two returns on the first floor. They did not think that the second return form the first floor should return by duct work to the furnace but should continue to empty into the basement. Please give me some advice here about what is right and what is wrong about this arrangement.
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    Nov 10, 2016, 06:05 PM
    They probably configured for what are called jump ducts. They act as mini returns and balance a system. I have them in most rooms in my house. There is no central return on the first floor?
    AMBEDFORD's Avatar
    AMBEDFORD Posts: 2, Reputation: 1
    New Member
     
    #3

    Nov 11, 2016, 09:21 AM
    Quote Originally Posted by ma0641 View Post
    They probably configured for what are called jump ducts. They act as mini returns and balance a system. I have them in most rooms in my house. There is no central return on the first floor?
    There are two returns on the first floor. Each one empties into the basement. However, upon my asking for the returns to be connected to the furnace directly, they decided to block one of the two returns. Now it feels as if the blocked return has cold air coming up into the first floor. What is going on here?

    Quote Originally Posted by AMBEDFORD View Post
    There are two returns on the first floor. Each one empties into the basement. However, upon my asking for the returns to be connected to the furnace directly, they decided to block one of the two returns. Now it feels as if the blocked return has cold air coming up into the first floor. What is going on here?
    The second return still empties into the basement and the two heat ducts in the basement they insist should stay open and hot air comes through very strongly. So, they have me heating the basement, seems like more than the house.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Should the flex hose on an intertherm electric furnace be connected [ 0 Answers ]

Should the flex duct hose be connected on my intertherm electric furnace?

HVAC Furnace will not light when exhaust pipe is connected... [ 0 Answers ]

At first our furnace heat wasn't coming on, we called our home warranty company and they sent out a HVAC guy. He replaced the inducer motor and the pressure switch. Then it still wasn't coming on properly so he said it was the exhaust or flu pipe that was blocked and we had to call a plumber to...

Dayton Furnace turning on without Thermostat connected [ 1 Answers ]

Hello, The title is a bit misleading... Some background. My Dayton furnace (less than 3 years old) had been working fine this winter. Yesterday, I caved and turned on the A/C, which was also working fine last summer. I noticed that the condenser was not kicking on. I checked the furnace...

2 thermostats connected to one furnace [ 0 Answers ]

I have a furnace that I would like to connect two thermostats to. I'd like to be able to control system when I'm in the basement or when I'm on the main floor.

Furnace-Yellow terminal not connected-A/C starts stops [ 3 Answers ]

I have a 1988 Rheem RGDA-125-ER furnace. I noticed over the summer that the A/C, when switched to cool, would come on and then immediately switch off if the set temp was higher than the room temp. If I programmed the set temp far below room temp and then switched on, it would run normally and I...


View more questions Search