    replace new honeywell thermostat
    I replaced an old 6 wired thermostat with an new honeywell RTh230B 5 wired

    old has
    o = orange
    r = red
    G1 = green
    Y = yellow
    W2 = whithe
    C = brown

    new I installed

    Rh = Red
    Rc = brown
    W = white
    Y = yellow
    G = green
    and orange not

    heating works, but manaul fan and cooling not
    how it should be
    wiener dog lover's Avatar
    wiener dog lover Posts: 1, Reputation: 1
    New Member
     
    #2

    Nov 17, 2007, 01:13 PM
    Quote Originally Posted by mimogimi
    i replaced an old 6 wired thermostat with an new honeywell RTh230B 5 wired

    old has
    o = orange
    r = red
    G1 = green
    Y = yellow
    W2 = whithe
    C = brown

    new i installed

    Rh = Red
    Rc = brown
    W = white
    Y = yellow
    G = green
    and orange not

    heating works, but manaul fan and cooling not
    how it should be
    Call the company
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #3

    Nov 17, 2007, 01:29 PM
    Wiener dog, that sure wasn't a DIY answer now was it. If you can't answer the question just let it go, someone else can actually help. Here is an old thread from Northernheat that explains the wiring https://www.askmehelpdesk.com/heatin...tml#post268211 Remember to jumper the two reds to each other Rh and Rc, this is done if you have but one 24 volt transformer.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Help to replace thermostat Honeywell T841a for Hunter 44155c [ 1 Answers ]

Hi, I am trying to replace my T841a 1712 Non-Programmable Heat Pump Universal Thermostat for a Hunter Model 44155C, but I can't make the new unit work.:confused: The Honeywell thermostat has the following connections: Color Cable Terminal Blue -----> X Red -----> W2 ...

Replace old Honeywell timer thermostat [ 19 Answers ]

I have 2 old Honeywell timer thermostats - on 2 floors - wired to my boiler (we have radiant water heating). Both function poorly and I would like to replace with standard round manual thermostats. Problem - I took one of the timer thermostats off the wall - it has 3 wires coming in - 2 black and...

Replace T87F thermostat with digital thermostat [ 1 Answers ]

My T87F has two wires Red and White. No code indicating how to connect to the new digital on.

Honeywell Chronotherm IV Plus Honeywell Thermostat, T8624D [ 1 Answers ]

Honeywell Deluxe Programmable Multistage Thermostat, #T8624D Chronotherm IV Plus I have 2 of above thermostats and have had for about 5 years. It takes no batteries and is directly connected to a 24 volt source. Have one upstairs and one downstairs. Have noticed at times that the LCD on...


View more questions Search