    R22 split system, many issues – which items to address first?
    Details: R22 split system. 2800 sq ft 2 story home. Have 10 year old Lennox 3 ton and 3.5 ton condensers. Have the following problems:

    If 90 outside (most of summer), upstairs does not cool below 80 (system turns on, runs the entire day).

    -Both condenser coils are corroded (hard water sprinkler system and dogs)

    -Duct work in attic is not sealed

    -Can lighting in attic is not sealed (26 total lights)

    -No attic fan present

    -Rolled R30 insulation, but some gaps


    If I cannot replace entire 10 year old system (attic components and condensers), which items on the list above would you address & if addressed how likely is it I would see good results without replacing entire system?

    Thanks in advance!
    thermalmedics's Avatar
    thermalmedics Posts: 153, Reputation: 13
    Junior Member
     
    #2

    Apr 30, 2012, 09:57 PM
    Of course I am an A/C guy so I have to say:

    Check the condenser coils outside. They can look like crap but are they clean and free of obstruction? Can air pass through the coils and up out of the top of the unit? If not clean coil.

    What is the supply air temp at the registers when it is running. Upper 50sto lower 60s or in the 70s? Is the air velocity good? Maybe dirty evap coil if temps are low but airflow also low.

    Seal up ductwork. Get a tub of pookie (duct mastic) real duct tape and some sheet metal screws and run the blower motor and find and seal all of the leaks. Insulate ductwork with bats of insulation

    Outside of that DIY your a/c for a good checkup or call a tech out that is not paid on commission.

    Good luck

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Is my r22 a/c split system over-charged or need cleaning? [ 0 Answers ]

I'm no A/C tech, just a DIYer with Fieldpiece diagnostic tools and a desire to learn. I have an Amana 12 SEER R-22, Non-TXV residential split A/C about 10 years old. My home is 2200 Sq Ft. located in Houston, TX. I was wondering if the high side reading is too high? If yes, would the...

R134a in an R22 system [ 4 Answers ]

What would the effects be if an r-22 system were to be evacuated and filled with R134a? What is the reason that this equipment can not handle this gas?

What is the best compressor oil to use a R22 system? [ 0 Answers ]

The system is on a freezer trawler. Flooded R22 system using 4 Grasso screw compressors

Do I have to replace the whole r22 system if I upsize from a 2 to a 2.5 ton r22 unit [ 6 Answers ]

My r22 heat pump unit is undersized for my house. It is a 2 ton and the builder should have installed a 2.5 ton. Do I have to replace the whole system, inside and out, if I upsize to a 2.5 ton or can I change out just the part that is the wrong size to cool the house? I can't really afford the cost...

How much more expenseve is a 410 system vs an r22 system [ 2 Answers ]

How much more expensive is a 410-a system vs an r-22 system


View more questions Search